Tie-down Straps and Screws, Replacing the DC/DC Converter Units and Air Dividers
View all HP Visualize J5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Figure 4-19. Tie-down Straps and Screws Field Replaceable Units (FRUs) FRU Removal and Replacement T-15 Torx screws Tie-down straps To remove the tie-downs: a. Remove the T-15 Torx screws securing the tie-downs to the rear air divider. b. Remove the T-15 Torx screws from the rear panel of the workstation. c. Rotate each tie-down out counterclockwise. The tab edge will unhinge from the fan wall. 4. Remove the rear air divider. 5. Remove the two captive screws on the DC/DC converter unit. 6. Grasp the DC/DC converter unit by the edges and pull it straight out from the system board. Replacing the DC/DC Converter Units and Air Dividers To replace the DC/DC converter units and air dividers, do the following: 1. Remove the J7000 workstation's top panel and left side panel. 2. Perform the previous removal procedure in reverse order. NOTE The two DC/DC converter units are interchangeable. The air flow holes on each unit should face inward to the center of the J7000's system board. Chapter 4 109