HP Visualize J5000 hp Visualize J5000, J7000 workstations service handbook (a4 - Page 71

Sbe&mbe Dimm, Mbe In Dimm

Page 71 highlights

Troubleshooting Identifying LCD-Indicated Conditions Table 3-1. Chassis Codes for J5000 and J7000 Workstations Ostat FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT FLT WRN Code FRU 7843 SYS BD 7844 SYS BD 7845 SYS BD 7846 7848 SYS BD SYS BD 785s DIMM 786s DIMM 787s DIMM 788s DIMM 7890 DIMM 7891 DIMM 7892 7893 7900 7901 7902 7903 7904 SYS BD SYS BD SYS BD SYS BD SYS BD SYS BD SYS BD 7905 79FF SYS BD SYS BD 80F3 SYS BD Message Description fwd prog invalid Memory forward progress word is invalid. mem HPMC summ wd Printing memory error summary word to RS-232. mem ctlr stat wd Printing memory controller status word to RS-232. mem err overflow Multiple memory errors detected. addr not mapped Memory address outside configured memory space. MBE in DIMM s Destructive memory test detected an uncorrectable memory error in DIMM s. SBE&MBE DIMM s Destructive memory test detected both an uncorrectable and a correctable memory error in DIMM s. mem err DIMM s Destructive memory test detected a pattern compare error in DIMM s. SBE in DIMM s Destructive memory test detected a correctable memory error in DIMM s. MBE overwrt SBE Firmware replaced a correctable memory error entry in the PDT with an uncorrectable memory error entry at the same address. dup entry in PDT The PDT already contains an entry at that address. PDT write error Error adding the entry to the PDT. PDT is full The PDT is full--cannot add new entry. no DMT entry Internal error--cannot find DIMM entry. no rank entry Internal error--cannot find rank entry. bad refrsh intvl Computed refresh interval is invalid. mem intrlv fail Cannot generate memory interleave. mem reloc failed Cannot interleave with relocated range (3.75GB - 4.0GB). mem intrlv error Undefined memory interleave failure. mem firmware err Internal error--never expected this to happen. err rd IODC byte Cannot read IODC from ROM or card. Chapter 3 67

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212

Chapter 3
67
Troubleshooting
Identifying LCD-Indicated Conditions
FLT
7843
SYS BD
fwd prog invalid
Memory forward progress word is invalid.
FLT
7844
SYS BD
mem HPMC summ wd
Printing memory error summary word to
RS-232.
FLT
7845
SYS BD
mem ctlr stat wd
Printing memory controller status word to
RS-232.
FLT
7846
SYS BD
mem err overflow
Multiple memory errors detected.
FLT
7848
SYS BD
addr not mapped
Memory address outside configured
memory space.
FLT
785
s
DIMM
MBE in DIMM
s
Destructive memory test detected an
uncorrectable memory error in DIMM
s
.
FLT
786
s
DIMM
SBE&MBE DIMM
s
Destructive memory test detected both an
uncorrectable and a correctable memory
error in DIMM
s
.
FLT
787
s
DIMM
mem err DIMM
s
Destructive memory test detected a
pattern compare error in DIMM
s
.
FLT
788
s
DIMM
SBE in DIMM
s
Destructive memory test detected a
correctable memory error in DIMM
s
.
FLT
7890
DIMM
MBE overwrt SBE
Firmware replaced a correctable memory
error entry in the PDT with an
uncorrectable memory error entry at the
same address.
FLT
7891
DIMM
dup entry in PDT
The PDT already contains an entry at
that address.
FLT
7892
SYS BD
PDT write error
Error adding the entry to the PDT.
FLT
7893
SYS BD
PDT is full
The PDT is full--cannot add new entry.
FLT
7900
SYS BD
no DMT entry
Internal error--cannot find DIMM entry.
FLT
7901
SYS BD
no rank entry
Internal error--cannot find rank entry.
FLT
7902
SYS BD
bad refrsh intvl
Computed refresh interval is invalid.
FLT
7903
SYS BD
mem intrlv fail
Cannot generate memory interleave.
FLT
7904
SYS BD
mem reloc failed
Cannot interleave with relocated range
(3.75GB - 4.0GB).
FLT
7905
SYS BD
mem intrlv error
Undefined memory interleave failure.
FLT
79FF
SYS BD
mem firmware err
Internal error--never expected this to
happen.
WRN
80F3
SYS BD
err rd IODC byte
Cannot read IODC from ROM or card.
Table 3-1. Chassis Codes for J5000 and J7000 Workstations
Ostat
Code
FRU
Message
Description