ASRock Z87 Extreme11/ac LSI Mega RAID Storage Manager Guide - Page 152
Managing Link Speed
View all ASRock Z87 Extreme11/ac manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 152 highlights
Foreign Configurations in Cable Pull and Drive Removal Scenarios If one or more drives are removed from a configuration, by a cable pull or drive removal, for example, the configuration on those drives is considered a foreign configuration by the RAID controller. The following scenarios can occur with cable pulls or drive removals. Use the Foreign Configuration Preview screen to import or clear the foreign configuration in each case. Note: If you want to import the foreign configuration in any of the following scenarios, you should have all of the drives in the enclosure before you perform the import operation. Scenario #1: If all of the drives in a configuration are removed and re-inserted, the controller considers the drives to have foreign configurations. - Import or clear the foreign configuration. If you select Import, automatic rebuilds will occur in redundant virtual drives. Note: Start a consistency check immediately after the rebuild is complete to ensure data integrity for the virtual drives. Scenario #2: If some of the drives in a configuration are removed and re-inserted, the controller considers the drives to have foreign configurations. - Import or clear the foreign configuration. If you select Import, automatic rebuilds will occur in redundant virtual drives. Note: Start a consistency check immediately after the rebuild is complete to ensure data integrity for the virtual drives. Scenario #3: If all of the drives in a virtual drive are removed, but at different times, and re-inserted, the controller considers the drives to have foreign configurations. - Import or clear the foreign configuration. If you select Import, all drives that were pulled before the virtual drive became offline will be imported and then automatically rebuilt. Automatic rebuilds will occur in redundant virtual drives. Scenario #4: If the drives in a non-redundant virtual drive are removed, the controller considers the drives to have foreign configurations. - Import or clear the foreign configuration. No rebuilds will occur after the import operation because there is no redundant data to rebuild the drives. Managing Link Speed The Managing Link Speed feature allows you to change the link speed between the controller and an expander or between the controller and a drive that is directly connected to the controller. All phys in a SAS port must have the same maximum link speed setting. If the phys in a SAS port have different link speeds, the firmware uses the lowest link speed for that SAS port. Follow these steps to change the link speed. 1. Right-click a controller in the left frame of the MegaRAID Storage Manager main menu and select Manage Link Speed. Page 152 DB09-000202-05 37857-02 Using the MegaRAID Advanced Software Rev. F - May 2011 Copyright © 2011 by LSI Corporation. All rights reserved.