ASRock Z87 Extreme11/ac LSI Mega RAID Storage Manager Guide - Page 169

Server Power capability Diagnostic Test Started

Page 169 highlights

Table 3 Event Messages (Cont.) Severity Number Level Event Text 0x018a Information Memory module FRU is %s 0x018b Warning Cache-vault power pack is sub-optimal. Please replace the pack 0x018c Warning Foreign configuration auto-import did not import any drives 0x018d Warning Cache-vault microcode update required 0x018e Warning CacheCade(TM) (%s) capacity exceeds maximum allowed size, extra capacity is not used 0x018f Warning LD (%s) protection information lost 0x0190 Information Diagnostics passed for %s 0x0191 Critical Diagnostics failed for %s 0x0192 Information Server Power capability Diagnostic Test Started 0x0193 Information Drive Cache settings enabled during rebuild for %s 0x0194 Information Drive Cache settings restored after rebuild for %s 0x0195 Information Drive %s commissioned as Emergency spare 0x0196 Warning Reminder: Potential non-optimal configuration due to drive %s commissioned as emergency spare 0x0197 Information Consistency Check suspended on %s 0x0198 Information Consistency Check resumed on %s 0x0199 Information Background Initialization suspended on %s 0x019a Information Background Initialization resumed on % 0x019b Information Reconstruction suspended on %s 0x019c Information Rebuild suspended on % 0x019d Information Copyback suspended on %s 0x019e Information Reminder: Consistency Check suspended on % 0x019f Information Reminder: Background Initialization suspended on %s 0x01a0 Information Reminder: Reconstruction suspended on %s 0x01a1 Information Reminder: Rebuild suspended on %s 0x01a2 Information Reminder: Copyback suspended on %s 0x01a3 Information Reminder: Patrol Read suspended 0x01a4 Information Erase aborted on %s 0x01a5 Critical Erase failed on %s (Error %02x) 0x01a6 Progress Erase progress on %s is %s DB09-000202-05 37857-02 Events and Messages Rev. F - May 2011 Copyright © 2011 by LSI Corporation. All rights reserved. Page 169

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Events and Messages
Page 169
DB09-000202-05 37857-02
Rev. F - May 2011
Copyright © 2011 by LSI Corporation. All rights reserved.
0x018a
Information
Memory module FRU is %s
0x018b
Warning
Cache-vault power pack is sub-optimal. Please replace the pack
0x018c
Warning
Foreign configuration auto-import did not import any drives
0x018d
Warning
Cache-vault microcode update required
0x018e
Warning
CacheCade(TM) (%s) capacity exceeds maximum allowed size, extra capacity is
not used
0x018f
Warning
LD (%s) protection information lost
0x0190
Information
Diagnostics passed for %s
0x0191
Critical
Diagnostics failed for %s
0x0192
Information
Server Power capability Diagnostic Test Started
0x0193
Information
Drive Cache settings enabled during rebuild for %s
0x0194
Information
Drive Cache settings restored after rebuild for %s
0x0195
Information
Drive %s commissioned as Emergency spare
0x0196
Warning
Reminder: Potential non-optimal configuration due to drive %s commissioned as
emergency spare
0x0197
Information
Consistency Check suspended on %s
0x0198
Information
Consistency Check resumed on %s
0x0199
Information
Background Initialization suspended on %s
0x019a
Information
Background Initialization resumed on %
0x019b
Information
Reconstruction suspended on %s
0x019c
Information
Rebuild suspended on %
0x019d
Information
Copyback suspended on %s
0x019e
Information
Reminder: Consistency Check suspended on %
0x019f
Information
Reminder: Background Initialization suspended on %s
0x01a0
Information
Reminder: Reconstruction suspended on %s
0x01a1
Information
Reminder: Rebuild suspended on %s
0x01a2
Information
Reminder: Copyback suspended on %s
0x01a3
Information
Reminder: Patrol Read suspended
0x01a4
Information
Erase aborted on %s
0x01a5
Critical
Erase failed on %s (Error %02x)
0x01a6
Progress
Erase progress on %s is %s
Table 3
Event Messages (Cont.)
Number
Severity
Level
Event Text