ASRock Z87 Extreme11/ac LSI Mega RAID Storage Manager Guide - Page 92

Scheduling a Consistency Check

Page 92 highlights

Figure 73 Set Consistency Check Properties 3. Choose one of the two options: - Stop Consistency Check on Error: The RAID controller stops the consistency check operation if the utility finds an error. - Continue Consistency Check and Fix Errors: The RAID controller continues the consistency check if the utility finds an error, and then fixes the error. 4. Click Ok. Scheduling a Consistency Check Follow these steps to set the properties for a consistency check: 1. Click the Physical tab or Logical tab in the main menu screen, and select the controller. 2. Select Go To->Controller->Schedule Consistency Check. The Schedule Consistency dialog appears, as shown in the following figure. Page 92 DB09-000202-05 37857-02 Maintaining and Managing Storage Configurations Rev. F - May 2011 Copyright © 2011 by LSI Corporation. All rights reserved.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Page 92
Maintaining and Managing Storage Configurations
DB09-000202-05 37857-02
Rev. F - May 2011
Copyright © 2011 by LSI Corporation. All rights reserved.
Figure 73
Set Consistency Check Properties
3.
Choose one of the two options:
Stop Consistency Check on Error
: The RAID controller stops the consistency check
operation if the utility finds an error.
Continue Consistency Check and Fix Errors
: The RAID controller continues the
consistency check if the utility finds an error, and then fixes the error.
4.
Click
Ok
.
Scheduling a Consistency Check
Follow these steps to set the properties for a consistency check:
1.
Click the
Physical
tab or
Logical
tab in the main menu screen, and select the controller.
2.
Select
Go To->Controller->Schedule Consistency Check
. The Schedule Consistency
dialog appears, as shown in the following figure.