ASRock Z87 Extreme11/ac LSI Mega RAID Storage Manager Guide - Page 164

Board Revision %s

Page 164 highlights

Table 3 Event Messages (Cont.) Severity Number Level Event Text 0x00fa Warning VD %s is now PARTIALLY DEGRADED 0x00fb Critical VD %s is now DEGRADED 0x00fc Fatal VD %s is now OFFLINE 0x00fd Warning Battery requires reconditioning; please initiate a LEARN cycle 0x00fe Warning VD %s disabled because RAID-5 is not supported by this RAID key 0x00ff Warning VD %s disabled because RAID-6 is not supported by this controller 0x0100 Warning VD %s disabled because SAS drives are not supported by this RAID key 0x0101 Warning PD missing: %s 0x0102 Warning Puncturing of LBAs enabled 0x0103 Warning Puncturing of LBAs disabled 0x0104 Critical Enclosure %s EMM %d not installed 0x0105 Information Package version %s 0x0106 Warning Global affinity Hot Spare %s commissioned in a different enclosure 0x0107 Warning Foreign configuration table overflow 0x0108 Warning Partial foreign configuration imported, PDs not imported:%s 0x0109 Information Connector %s is active 0x010a Information Board Revision %s 0x010b Warning Command timeout on PD %s, CDB:%s 0x010c Warning PD %s reset (Type %02x) 0x010d Warning VD bad block table on %s is 80% full 0x010e Fatal VD bad block table on %s is full; unable to log block %lx (on %s at %lx) 0x010f Fatal Uncorrectable medium error logged for %s at %lx (on %s at %lx) 0x0110 Information VD medium error corrected on %s at %lx 0x0111 Warning Bad block table on PD %s is 100% full 0x0112 Warning VD bad block table on PD %s is 100% full 0x0113 Fatal Controller needs replacement, IOP is faulty 0x0114 Information CopyBack started on PD %s from PD %s 0x0115 Information CopyBack aborted on PD %s and src is PD %s 0x0116 Information CopyBack complete on PD %s from PD %s 0x0117 Progress CopyBack progress on PD %s is %s Page 164 DB09-000202-05 37857-02 Events and Messages Rev. F - May 2011 Copyright © 2011 by LSI Corporation. All rights reserved.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Page 164
Events and Messages
DB09-000202-05 37857-02
Rev. F - May 2011
Copyright © 2011 by LSI Corporation. All rights reserved.
0x00fa
Warning
VD %s is now PARTIALLY DEGRADED
0x00fb
Critical
VD %s is now DEGRADED
0x00fc
Fatal
VD %s is now OFFLINE
0x00fd
Warning
Battery requires reconditioning; please initiate a LEARN cycle
0x00fe
Warning
VD %s disabled because RAID-5 is not supported by this RAID key
0x00ff
Warning
VD %s disabled because RAID-6 is not supported by this controller
0x0100
Warning
VD %s disabled because SAS drives are not supported by this RAID key
0x0101
Warning
PD missing: %s
0x0102
Warning
Puncturing of LBAs enabled
0x0103
Warning
Puncturing of LBAs disabled
0x0104
Critical
Enclosure %s EMM %d not installed
0x0105
Information
Package version %s
0x0106
Warning
Global affinity Hot Spare %s commissioned in a different enclosure
0x0107
Warning
Foreign configuration table overflow
0x0108
Warning
Partial foreign configuration imported, PDs not imported:%s
0x0109
Information
Connector %s is active
0x010a
Information
Board Revision %s
0x010b
Warning
Command timeout on PD %s, CDB:%s
0x010c
Warning
PD %s reset (Type %02x)
0x010d
Warning
VD bad block table on %s is 80% full
0x010e
Fatal
VD bad block table on %s is full; unable to log block %lx (on %s at %lx)
0x010f
Fatal
Uncorrectable medium error logged for %s at %lx (on %s at %lx)
0x0110
Information
VD medium error corrected on %s at %lx
0x0111
Warning
Bad block table on PD %s is 100% full
0x0112
Warning
VD bad block table on PD %s is 100% full
0x0113
Fatal
Controller needs replacement, IOP is faulty
0x0114
Information
CopyBack started on PD %s from PD %s
0x0115
Information
CopyBack aborted on PD %s and src is PD %s
0x0116
Information
CopyBack complete on PD %s from PD %s
0x0117
Progress
CopyBack progress on PD %s is %s
Table 3
Event Messages (Cont.)
Number
Severity
Level
Event Text