ASRock Z87 Extreme11/ac LSI Mega RAID Storage Manager Guide - Page 162

Background Initialization BGI Aborted Due to Ownership Loss on %s

Page 162 highlights

Table 3 Event Messages (Cont.) Severity Number Level Event Text 0x00bf Information Clustering enabled 0x00c0 Information Clustering disabled 0x00c1 Information Drive too small to be used for auto-rebuild on %s 0x00c2 Information BBU enabled; changing WT virtual drives to WB 0x00c3 Warning BBU disabled; changing WB virtual drives to WT 0x00c4 Warning Bad block table on drive %s is 80% full 0x00c5 Fatal Bad block table on drive %s is full; unable to log block %lx 0x00c6 Information Consistency Check Aborted due to ownership loss on %s 0x00c7 Information Background Initialization (BGI) Aborted Due to Ownership Loss on %s 0x00c8 Critical Battery/charger problems detected; SOH Bad 0x00c9 Warning Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning threshold exceeded 0x00ca Critical Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical threshold exceeded 0x00cb Critical Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further reporting disabled 0x00cc Critical Enclosure %s Power supply %d switched off 0x00cd Information Enclosure %s Power supply %d switched on 0x00ce Critical Enclosure %s Power supply %d cable removed 0x00cf Information Enclosure %s Power supply %d cable inserted 0x00d0 Information Enclosure %s Fan %d returned to normal 0x00d1 Information BBU Retention test was initiated on previous boot 0x00d2 Information BBU Retention test passed 0x00d3 Critical BBU Retention test failed! 0x00d4 Information NVRAM Retention test was initiated on previous boot 0x00d5 Information NVRAM Retention test passed 0x00d6 Critical NVRAM Retention test failed! 0x00d7 Information %s test completed %d passes successfully 0x00d8 Critical %s test FAILED on %d pass. Fail data: errorOffset=%x goodData=%x badData=%x 0x00d9 Information Self check diagnostics completed 0x00da Information Foreign Configuration detected 0x00db Information Foreign Configuration imported 0x00dc Information Foreign Configuration cleared Page 162 DB09-000202-05 37857-02 Events and Messages Rev. F - May 2011 Copyright © 2011 by LSI Corporation. All rights reserved.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178

Page 162
Events and Messages
DB09-000202-05 37857-02
Rev. F - May 2011
Copyright © 2011 by LSI Corporation. All rights reserved.
0x00bf
Information
Clustering enabled
0x00c0
Information
Clustering disabled
0x00c1
Information
Drive too small to be used for auto-rebuild on %s
0x00c2
Information
BBU enabled; changing WT virtual drives to WB
0x00c3
Warning
BBU disabled; changing WB virtual drives to WT
0x00c4
Warning
Bad block table on drive %s is 80% full
0x00c5
Fatal
Bad block table on drive %s is full; unable to log block %lx
0x00c6
Information
Consistency Check Aborted due to ownership loss on %s
0x00c7
Information
Background Initialization (BGI) Aborted Due to Ownership Loss on %s
0x00c8
Critical
Battery/charger problems detected; SOH Bad
0x00c9
Warning
Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); warning threshold exceeded
0x00ca
Critical
Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); critical threshold exceeded
0x00cb
Critical
Single-bit ECC error: ECAR=%x, ELOG=%x, (%s); further reporting disabled
0x00cc
Critical
Enclosure %s Power supply %d switched off
0x00cd
Information
Enclosure %s Power supply %d switched on
0x00ce
Critical
Enclosure %s Power supply %d cable removed
0x00cf
Information
Enclosure %s Power supply %d cable inserted
0x00d0
Information
Enclosure %s Fan %d returned to normal
0x00d1
Information
BBU Retention test was initiated on previous boot
0x00d2
Information
BBU Retention test passed
0x00d3
Critical
BBU Retention test failed!
0x00d4
Information
NVRAM Retention test was initiated on previous boot
0x00d5
Information
NVRAM Retention test passed
0x00d6
Critical
NVRAM Retention test failed!
0x00d7
Information
%s test completed %d passes successfully
0x00d8
Critical
%s test FAILED on %d pass. Fail data: errorOffset=%x goodData=%x badData=%x
0x00d9
Information
Self check diagnostics completed
0x00da
Information
Foreign Configuration detected
0x00db
Information
Foreign Configuration imported
0x00dc
Information
Foreign Configuration cleared
Table 3
Event Messages (Cont.)
Number
Severity
Level
Event Text