EPSON Stylus Pro 9000 REMOVING THE PAPER THICKNESS SENSOR Preparation: Remove the Maintenance Cover as described in Maintenance Cover Removal on page 58. Remove the Top Cover as described in Top Cover Removal on page 59. Remove the Right Side Cover as described in Left and Right Side Cover Removal on page 60. 1. Disconnect the cable from CN12 on the relay board on the right side of the printer. 2. Remove the two screws (CP(W) M3x6) securing the Paper Thickness Sensor, and remove the sensor. REMOVING THE REAR PAPER SENSOR Preparation: Remove the Maintenance Cover as described in Maintenance Cover Removal on page 58. Remove the Top Cover as described in Top Cover Removal on page 59. Remove the Upper Paper Guide as described in Upper Paper Guide Removal on page 64. 1. Disconnect the cable from CN11 on the C277MAIN board. 2. Remove the screw (CP(W) M3x6) securing the Rear Paper Sensor, and remove the sensor. Figure 4-39. Paper Thickness Sensor Removal Perform the Paper Thickness Sensor Adjustment on page 134. Disassembly & Assembly Figure 4-40. Rear Paper Sensor Removal Perform the Rear Sensor Position Adjustment on page 126. 80