Yamaha LS9-32 Owner's Manual - Page 141

If you want to enable Recall Safe for spe, cific parameters of the selected channel

Page 141 highlights

3 If you want to enable Recall Safe for specific parameters of the selected channel, make the following settings in the SAFE PARAMETER field. ● For an input channel Use the buttons in the lower part of the SAFE PARAMETER field (except for the "ALL" button) to select the parameters that will be subject to Recall Safe (multiple selections are allowed). If you want all parameters to be subject to Recall Safe, turn on the ALL button (this is the default setting). Using the Recall Safe function ● If a STEREO/MONO channel is selected With the exception of the types of button that are displayed, this is the same as for an input channel. LS9-16 LS9-32 These buttons correspond to the following parameters. Button name ALL HA EQ DYNA 1 DYNA 2 MIX ON MIX SEND FADER CH ON Corresponding parameters All parameters Head amp settings (including external HA) EQ settings (including ATT/HPF) Dynamics 1 settings Dynamics 2 settings On/off status of signals sent to MIX buses Send levels of signals sent to MIX buses Fader positions On/off status of [ON] keys NOTE • If you turn on the ALL button, all other buttons of the SAFE PARAMETER field will be turned off. These buttons correspond to the following parameters. Button name ALL EQ DYNA 1 MTRX ON MTRX SEND FADER CH ON Corresponding parameters All parameters EQ settings (including ATT) Dynamics 1 settings On/off status of signals sent to MATRIX buses Send levels of signals sent to MATRIX buses Fader positions On/off status of [ON] keys ● If a MIX channel is selected Use the buttons in the lower part of the SAFE PARAMETER field (except for the "ALL" button) to select the parameters that will be subject to Recall Safe (multiple selections are allowed). In addition, you can use the WITH MIX SEND button to enable Recall Safe for the on/off status and send level of the signals sent from input channels to MIX buses. If you want all parameters shown in the lower part of the field to be subject to Recall Safe, turn on the ALL button (this is the default setting). Scene memory 13 LS9-16/32 Owner's Manual 141

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290

141
Using the Recall Safe function
LS9-16/32
Owner’s Manual
13
Scene memory
3
If you want to enable Recall Safe for spe-
cific parameters of the selected channel,
make the following settings in the SAFE
PARAMETER field.
For an input channel
Use the buttons in the lower part of the SAFE
PARAMETER field (except for the “ALL” button) to
select the parameters that will be subject to Recall
Safe (multiple selections are allowed). If you want all
parameters to be subject to Recall Safe, turn on the
ALL button (this is the default setting).
These buttons correspond to the following parameters.
If a STEREO/MONO channel is selected
With the exception of the types of button that are dis-
played, this is the same as for an input channel.
These buttons correspond to the following parameters.
If a MIX channel is selected
Use the buttons in the lower part of the SAFE
PARAMETER field (except for the “ALL” button) to
select the parameters that will be subject to Recall
Safe (multiple selections are allowed).
In addition, you can use the WITH MIX SEND button
to enable Recall Safe for the on/off status and send
level of the signals sent from input channels to MIX
buses.
If you want all parameters shown in the lower part of
the field to be subject to Recall Safe, turn on the ALL
button (this is the default setting).
Button name
Corresponding parameters
ALL
All parameters
HA
Head amp settings (including external HA)
EQ
EQ settings (including ATT/HPF)
DYNA 1
Dynamics 1 settings
DYNA 2
Dynamics 2 settings
MIX ON
On/off status of signals sent to MIX buses
MIX SEND
Send levels of signals sent to MIX buses
FADER
Fader positions
CH ON
On/off status of [ON] keys
LS9-16
LS9-32
If you turn on the ALL button, all other buttons of the SAFE
PARAMETER field will be turned off.
NOTE
Button name
Corresponding parameters
ALL
All parameters
EQ
EQ settings (including ATT)
DYNA 1
Dynamics 1 settings
MTRX ON
On/off status of signals sent to MATRIX buses
MTRX SEND
Send levels of signals sent to MATRIX buses
FADER
Fader positions
CH ON
On/off status of [ON] keys