Yamaha LS9-32 Owner's Manual - Page 212

Operations on the cascade master LS9, CASCADE IN PATCH popup window.

Page 212 highlights

Using cascade connections Operations on the cascade master LS9 1 In the DISPLAY ACCESS section, press the [SETUP] key repeatedly to access the SYSTEM SETUP screen. 2 In the MIXER SETUP field located at the lower part of the SYSTEM SETUP screen, move the cursor to the CASCADE IN button and press the [ENTER] key to access the CASCADE IN PATCH popup window. The CASCADE IN PATCH popup window contains the following items. 1 [ INPUT PORT SELECT popup window for the LS9-32 ] 2 1 [ INPUT PORT SELECT popup window for the LS9-16 ] 1 2 3 1 Port select popup buttons These buttons access the INPUT PORT SELECT popup window, where you can select the input port whose signal will be added to the bus. B CASCADE LINK PORT field Here you can select the port that will transmit and receive control signals when using the Cascade Link function to link specific operations and parameter changes between two LS9 consoles. C CASCADE COMM LINK field Here you can select the parameters and events that will be linked by the Cascade Link function. 3 Move the cursor to the port select popup button for the bus whose port you want to assign, and press the [ENTER] key. The INPUT PORT SELECT popup window will appear. This popup window contains the following items. This popup window contains the following items. 1 Port select buttons Here you can select the input port whose signal will be added to the selected bus. B Slot select tabs (LS9-32 only) These tabs select slots 1/2. 4 Use the port select buttons {slot select tabs and port select buttons} to select an input port, move the cursor to the CLOSE button and press the [ENTER] key. The input port will be assigned to the bus you selected in step 3. The signal input from this port will be mixed with the signal of the corresponding bus inside the cascade master. 5 Repeat steps 3 and 4 to assign input ports to other buses. NOTE • You can't assign the same input port to two or more buses. If you select a bus to which a signal route has already been assigned, the previous assignment will be cancelled. 212 LS9-16/32 Owner's Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290

212
Using cascade connections
LS9-16/32
Owner’s Manual
1
In the DISPLAY ACCESS section, press the
[SETUP] key repeatedly to access the SYS-
TEM SETUP screen.
2
In the MIXER SETUP field located at the
lower part of the SYSTEM SETUP screen,
move the cursor to the CASCADE IN button
and press the [ENTER] key to access the
CASCADE IN PATCH popup window.
The CASCADE IN PATCH popup window contains
the following items.
1
Port select popup buttons
These buttons access the INPUT PORT SELECT
popup window, where you can select the input port
whose signal will be added to the bus.
B
CASCADE LINK PORT field
Here you can select the port that will transmit and
receive control signals when using the Cascade Link
function to link specific operations and parameter
changes between two LS9 consoles.
C
CASCADE COMM LINK field
Here you can select the parameters and events that will
be linked by the Cascade Link function.
3
Move the cursor to the port select popup
button for the bus whose port you want to
assign, and press the [ENTER] key.
The INPUT PORT SELECT popup window will
appear.
This popup window contains the following items.
[ INPUT PORT SELECT popup window for
the LS9-32 ]
[ INPUT PORT SELECT popup window for
the LS9-16 ]
This popup window contains the following items.
1
Port select buttons
Here you can select the input port whose signal will be
added to the selected bus.
B
Slot select tabs (LS9-32 only)
These tabs select slots 1/2.
4
Use the port select buttons {slot select tabs
and port select buttons} to select an input
port, move the cursor to the CLOSE button
and press the [ENTER] key.
The input port will be assigned to the bus you selected
in step 3. The signal input from this port will be mixed
with the signal of the corresponding bus inside the cas-
cade master.
5
Repeat steps 3 and 4 to assign input ports
to other buses.
Operations on the cascade master
LS9
1
2
3
2
1
1
You can’t assign the same input port to two or more buses. If
you select a bus to which a signal route has already been
assigned, the previous assignment will be cancelled.
NOTE