HP Cluster Platform Interconnects v2010 Quadrics QsNetII Interconnect - Page 137

Table A-3: Federated Clusters of 129-256 Nodes, Reduced Bandwidth

Page 137 highlights

Federated Clusters of 129-256 Nodes, Reduced Bandwidth The following parts list specifies the parts that are the same for all node counts: Part Top level interconnect enclosure (uses a transpose midplane that has no link connectors). Transpose midplane with no link connectors Top level interconnect, rear cards QM502 Top level interconnect, front cards QM502 Quantity 1 1 4 4 The following table specifies the additional parts and count required, depending number of nodes in the cluster: Table A-3: Federated Clusters of 129-256 Nodes, Reduced Bandwidth Nodes NLI NLI Rear Cards NLI Front Link Cables Cards Total IC Total TP Midplane Total QM501 Total QM502 QM501 QM502 129-144 3 9 6 96+nodes 4 3 9 14 145-160 3 10 6 96+nodes 4 3 10 14 161-176 3 11 6 96+nodes 4 3 11 14 177-192 3 12 6 96+nodes 4 3 12 14 193-208 4 13 8 128+nodes 5 4 13 16 209-224 4 14 8 128+nodes 5 4 14 16 225-240 4 15 8 128+nodes 5 4 15 16 241-256 4 16 8 128+nodes 5 4 16 16 Federated Clusters of 129-256 Nodes, Full Bandwidth The following parts list specifies the parts that are the same for all node counts: Part Top level interconnect enclosure (uses a transpose midplane that has no link connectors). Top level interconnect, rear cards QM502 Top level interconnect, front cards QM502 Quantity 2 8 8 The following table specifies the additional parts and count required, depending number of nodes in the cluster: Table A-4: Federated Clusters of 129-256 Nodes, Full Bandwidth Nodes NLI NLI Rear Cards NLI Front Link Cables Cards Total IC Total TP Total QM501 Midplane QM501 QM502 129 - 144 3 9 12 172+nodes 5 3 9 145 - 160 3 10 12 172+nodes 5 3 10 161 - 176 3 11 12 172+nodes 5 3 11 177 - 192 3 12 12 172+nodes 5 3 12 193 - 208 4 13 16 256+nodes 6 4 13 209 - 224 4 14 16 256+nodes 6 4 14 225 - 240 4 15 16 256+nodes 6 4 15 241 - 256 4 16 16 256+nodes 6 4 16 Total QM502 28 28 28 28 32 32 32 32 Components Required A-3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Federated Clusters of 129-256 Nodes, Reduced Bandwidth
The following parts list specifies the parts that are the same for all node counts:
Part
Quantity
Top level interconnect enclosure (uses a transpose
midplane that has no link connectors).
1
Transpose midplane with no link connectors
1
Top level interconnect, rear cards QM502
4
Top level interconnect, front cards QM502
4
The following table specifies the additional parts and count required, depending
number of nodes in the cluster:
Table A-3: Federated Clusters of 129-256 Nodes, Reduced Bandwidth
Nodes
NLI
NLI Rear
Cards
QM501
NLI Front
Cards
QM502
Link Cables
Total IC
Total TP
Midplane
Total QM501
Total
QM502
129–144
3
9
6
96+nodes
4
3
9
14
145–160
3
10
6
96+nodes
4
3
10
14
161–176
3
11
6
96+nodes
4
3
11
14
177–192
3
12
6
96+nodes
4
3
12
14
193–208
4
13
8
128+nodes
5
4
13
16
209–224
4
14
8
128+nodes
5
4
14
16
225–240
4
15
8
128+nodes
5
4
15
16
241–256
4
16
8
128+nodes
5
4
16
16
Federated Clusters of 129-256 Nodes, Full Bandwidth
The following parts list specifies the parts that are the same for all node counts:
Part
Quantity
Top level interconnect enclosure (uses a transpose
midplane that has no link connectors).
2
Top level interconnect, rear cards QM502
8
Top level interconnect, front cards QM502
8
The following table specifies the additional parts and count required, depending
number of nodes in the cluster:
Table A-4: Federated Clusters of 129-256 Nodes, Full Bandwidth
Nodes
NLI
NLI Rear
Cards
QM501
NLI Front
Cards
QM502
Link Cables
Total IC
Total TP
Midplane
Total QM501
Total QM502
129 – 144
3
9
12
172+nodes
5
3
9
28
145 – 160
3
10
12
172+nodes
5
3
10
28
161 – 176
3
11
12
172+nodes
5
3
11
28
177 – 192
3
12
12
172+nodes
5
3
12
28
193 – 208
4
13
16
256+nodes
6
4
13
32
209 – 224
4
14
16
256+nodes
6
4
14
32
225 – 240
4
15
16
256+nodes
6
4
15
32
241 – 256
4
16
16
256+nodes
6
4
16
32
Components Required
A-3