HP Cluster Platform Interconnects v2010 Quadrics QsNetII Interconnect - Page 41

Controller Signal LEDs

Page 41 highlights

Color Interpre- Normal Status tation Alternate Status Green Link Illuminated if the link is function functioning. Unlit if the link has a problem or is disconnected. Yellow Link Illuminated or flashing if data Unlit if no data is passing activity traffic is passing through the link. through the link. Red Link error Off. On - there is an error on the link.a a The red LED illuminates after you connect a link to a node because the link resets when the node boots. The LED will go off after the node has booted. Figure 4-3 shows the location of the signal LEDs on the controller module. Figure 4-3: Controller Signal LEDs 31 30 29 28 Pri Clk Sec Clk Clk Err VGA KYBD 10/100 BASE T CLKA/CLKB COM 1 RESET Pwr On Ctrl Run Ctrl Err These LEDs provide the following information: LED Pri Clk Sec Clk Color Green Green Clk Err Red Pwr On Green Ctrl Run Green Interpretation Error Status Primary clock input is good. (Federated mode only). Off Secondary clock input is good. (Federated Off mode only). Clock error is detected. On Switch is powered on. When power is applied, Off the cooling fans must be running. If you do not see or hear the fans, switch off the interconnect. See Section 8.2. The controller CPU has booted and is Off running normally.a Ctrl Err Red The controller CPU watchdog has timed out On a After cycling the power or resetting the controller, you must allow five minutes for the Ctrl Run LED to illuminate. The function of the ports on the controller card is identical to that of the 128-port interconnect chassis. 16/32-Port Interconnect 4-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166

Color
Interpre-
tation
Normal Status
Alternate Status
Green
Link
function
Illuminated if the link is
functioning.
Unlit if the link has a problem
or is disconnected.
Yellow
Link
activity
Illuminated or flashing if data
traffic is passing through the link.
Unlit if no data is passing
through the link.
Red
Link error Off.
On – there is an error on the link.
a
a
The red LED illuminates after you connect a link to a node because the link resets when the node boots. The
LED will go off after the node has booted.
Figure 4-3 shows the location of the signal LEDs on the controller module.
Figure 4-3: Controller Signal LEDs
Pri Clk
Sec Clk
Clk Err
VGA
KYBD
10/100
BASE T
CLKA/CLKB
COM 1
RESET
Pwr On
Ctrl Run
Ctrl Err
31
30
29
28
These LEDs provide the following information:
LED
Color
Interpretation
Error Status
Pri Clk
Green
Primary clock input is good. (Federated mode only). Off
Sec Clk
Green
Secondary clock input is good. (Federated
mode only).
Off
Clk Err
Red
Clock error is detected.
On
Pwr On
Green
Switch is powered on. When power is applied,
the cooling fans must be running. If you
do not see or hear the fans, switch off the
interconnect. See Section 8.2.
Off
Ctrl Run
Green
The controller CPU has booted and is
running normally.
a
Off
Ctrl Err
Red
The controller CPU watchdog has timed out
On
a
After cycling the power or resetting the controller, you must allow five minutes for the Ctrl Run LED to illuminate.
The function of the ports on the controller card is identical to that of the 128–port
interconnect chassis.
16/32-Port Interconnect