Netgear GS724TPv2 User Manual - Page 62

Table 13., PoE Port Configuration, Set Up PoE, Timer Schedules

Page 62 highlights

NETGEAR 24-Port Gigabit Smart Managed Pro Switch with PoE+ and 2 SFP Ports Model GS724TPv2 For information about setting up and configuring PoE timer schedules, see Set Up PoE Timer Schedules on page 87. 12. Click the Apply button. The updated configuration is sent to the switch. Configuration changes take effect immediately. The following table describes the nonconfigurable fields on the page. Table 13. PoE Port Configuration Field High Power Max Power Class Output Voltage Output Current Output Power Status Fault Status Description All ports supports high-power mode. The maximum power in milliwatts that can be provided by the port. The class defines the range of power that a powered device (PD) is drawing from the switch. The class definitions are as follows: • 0: 0.44-12.95W • 1: 0.44-3.83W • 2: 0.44-6.48W • 3: 0.44-12.95W • 4: 0.44-25.5W The voltage that is delivered to the PD in volts. The current that is delivered to the PD in mA. The power that is delivered to the PD in watts. The operational status of the port. The possible values are as follows: • Disabled. No power is delivered. • DeliveringPower. Power is being drawn by the PD. • Fault. A problem occurred with the power. • Test. The port is in test mode. • otherFault. The port is idle because of an error condition. • Searching. The port is not in one of the other states in this list. The error description when the PoE port is in a fault state. The possible values are as follows: • No Error. The port is not in any error state and can provide power. • MPS Absent. The port detected the absence of the main power supply, preventing the port from providing power. • Short. The port detected a short circuit condition, preventing the port from providing power. • Overload. The PD that is connected to the port attempts to draw more power than allowed by the port's settings, preventing the port from providing power at all. • Power Denied. The port was denied power because of a shortage of power or because of an administrative condition. In this condition, the port cannot provide power. Configure System Information 62

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307
  • 308
  • 309
  • 310
  • 311
  • 312
  • 313
  • 314
  • 315
  • 316
  • 317

Configure System Information
62
NETGEAR 24-Port Gigabit Smart Managed Pro Switch with PoE+ and 2 SFP Ports Model GS724TPv2
For information about setting up and configuring PoE timer schedules, see
Set Up PoE
Timer Schedules
on page 87.
12.
Click the
Apply
button.
The updated configuration is sent to the switch. Configuration changes take effect
immediately.
The following table describes the nonconfigurable fields on the page.
Table 13.
PoE Port Configuration
Field
Description
High Power
All ports supports high-power mode.
Max Power
The maximum power in milliwatts that can be provided by the port.
Class
The class defines the range of power that a powered device (PD) is drawing from
the switch. The class definitions are as follows:
0
: 0.44–12.95W
1
: 0.44–3.83W
2
: 0.44–6.48W
3
: 0.44–12.95W
4
: 0.44–25.5W
Output Voltage
The voltage that is delivered to the PD in volts.
Output Current
The current that is delivered to the PD in mA.
Output Power
The power that is delivered to the PD in watts.
Status
The operational status of the port. The possible values are as follows:
Disabled
. No power is delivered.
DeliveringPower
. Power is being drawn by the PD.
Fault
. A problem occurred with the power.
Test
. The port is in test mode.
otherFault
. The port is idle because of an error condition.
Searching
. The port is not in one of the other states in this list.
Fault Status
The error description when the PoE port is in a fault state. The possible values are
as follows:
No Error
. The port is not in any error state and can provide power.
MPS Absent
. The port detected the absence of the main power supply,
preventing the port from providing power.
Short
. The port detected a short circuit condition, preventing the port from
providing power.
Overload
. The PD that is connected to the port attempts to draw more power
than allowed by the port’s settings, preventing the port from providing power at
all.
Power Denied
. The port was denied power because of a shortage of power or
because of an administrative condition. In this condition, the port cannot
provide power.