Yamaha QL5 Reference Manual - Page 253

System Realtime Message, Song Select, Timing Clock, Active Sensing, System Reset, Bulk Dump

Page 253 highlights

2 SYSTEM REALTIME MESSAGE 2.1 SONG SELECT (F3) Reception Select the track number shown in the TITLE LIST screen of the USB memory recorder. STATUS 11110011 F3 Song select Song number 0sssssss ss Song number (0-127) 2.2 TIMING CLOCK (F8) Reception This message is used to control effects. This message is transmitted twenty-four times per quarter note. Echoing of this message depends on the OTHER item in the ECHO settings. STATUS 11111000 F8 Timing clock 2.3 ACTIVE SENSING (FE) Reception Once this message has been received, MIDI communication will be initialized (e.g., Running Status will be cleared) if no message is received for an interval of 400 ms. This message is not subject to echoing. STATUS 11111110 FE Active sensing 2.4 SYSTEM RESET (FF) Reception When this message is received, MIDI communication will be initialized (e.g., Running Status will be cleared). This message is not subject to echoing. STATUS 11111111 FF System reset 3 SYSTEM EXCLUSIVE MESSAGE 3.1 MMC < MMC STOP > Reception If the [DEVICE NO.] matches or is 7F, receives this message and stops. STATUS ID No. Device ID COMMAND EOX 11110000 F0 01111111 7F 0ddddddd dd 00000110 06 00000001 01 11110111 F7 System exclusive message Real time System exclusive Destination (00-7E, 7F:all call) Machine Control Command(MCC) sub-id Stop(MCS) End of exclusive < MMC PLAY > Reception If the [DEVICE NO.] matches or is 7F, receives this message and starts playback. STATUS ID No. Device ID COMMAND EOX 11110000 F0 01111111 7F 0ddddddd dd 00000110 06 00000010 02 11110111 F7 System exclusive message Real time System exclusive Destination (00-7E, 7F:all call) Machine Control Command(MCC) sub-id Play(MCS) End of exclusive < MMC DEFERED PLAY > Reception If the [DEVICE NO.] matches or is 7F, receives this message and starts playback. STATUS ID No. Device ID COMMAND EOX 11110000 F0 01111111 7F 0ddddddd dd 00000110 06 00000011 03 11110111 F7 System exclusive message Real time System exclusive Destination (00-7E, 7F:all call) Machine Control Command(MCC) sub-id Deferred Play(MCS) End of exclusive < MMC RECORD STROBE > Reception If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts recording. STATUS ID No. Device ID COMMAND EOX 11110000 F0 01111111 7F 0ddddddd dd 00000110 06 00000110 06 11110111 F7 System exclusive message Real time System exclusive Destination (00-7E, 7F:all call) Machine Control Command(MCC) sub-id Record strobe End of exclusive < MMC PAUSE > Reception If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses. STATUS ID No. Device ID COMMAND EOX 11110000 F0 01111111 7F 0ddddddd dd 00000110 06 00001001 09 11110111 F7 System exclusive message Real time System exclusive Destination (00-7E, 7F:all call) Machine Control Command(MCC) sub-id Pause(MCS) End of exclusive 3.2 BULK DUMP This message is used to send or receive the contents of various memories stored within the unit. The basic format is as follows. Command F0 43 0n 3E cc cc 19 mm ... mm dd dd ... ee F7 F0 43 2n 3E 19 mm ... mm dd dd F7 rx/tx rx/tx rx Function BULK DUMP DATA BULK DUMP REQUEST The QL series console uses the following data types for a bulk dump. Module Name(mm) SCENE LIB INPUT EQ LIB OUTPUT EQ LIB Dynamics LIB INPUT CH LIB OUTPUT CH LIB GEQ LIB EFFECT LIB Premium Effect Portico5033 LIB Portico5043 LIB U76 LIB Opt-2A LIB "SCENE___" "INEQ____" "OUTEQ___" "DYNA____" "INCHNNL_" "OUTCHNNL" "GEQ_____" "EFFECT__" "PEFFECT_" "P5033___" "P5043___" "U76_____" "OPT-2A__" Data Number(dd) *1) *14) *15) *16) *2) *7) *8) *3) *9) *10) *11) *4) *7) *8) *9) *10) *11) *21) *22) *17) *7) *8) *18) *9) *10) *11) *5) *12) *6) *13) *19) *20) *20) *20) *20) Module Name(mm) EQP-1A LIB DynamicEQ LIB Dante Input Patch LIB Mixer Setup Outport Setup Monitor Setup MIDI Setup Lib Number Program Change Table Control Change Table Preference (Current) Preference (Admin) Preference (Guest) User Defined Keys (Current) User Defined Keys (Admin) User Defined Keys (Guest) Custom Fader Bank (Current) Custom Fader Bank (Admin) Custom Fader Bank (Guest) User Level (Current) User Level (Guest) "EQ-1A___" "DYNAEQ__" "DANTEIN_" "MIXERSET" "OUT_PORT" "MONITOR_" "MIDI_SET" "LIB_NUM_" "PRGMCHG_" "CTRLCHG_" "PREF_CUR" "PREF_ADM" "PREF_GST" "UDEF_CUR" "UDEF_ADM" "UDEF_GST" "CFAD_CUR" "CFAD_ADM" "CFAD_GST" "UKEY_CUR" "UKEY_GST" Data Number(dd) *20) *20) *23) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) include Knob, Encoder Fix (512) include Knob, Encoder Fix (512) include Knob, Encoder Fix (512) Fix (512) Fix (512) Fix (512) Fix (512) *1) 0-300 Scene Number (0 Request Only), *2) 1-199 Input EQ Library Number (1-40 Request Only) *3) 1-199 Output EQ Library Number (1-3 Request Only) *4) 1-199 Dynamics Library Number (1-41 Request Only) *5) 0-199 GEQ Library Number (0 Request Only) *6) 1-199 Effect Library Number (1-27 Request Only) *7) 512-583 Input 1-64, *8) 584-599 STIN 1L-8R, *9) 768-791 MIX 1-16, *10) 1024-1031 MATRIX 1-8, *11) 1280-1282 STEREO L-C, *12) 512-530 GEQ 1-19, 531-538 EFFECT GEQ 1-8, *13) 512-519 EFFECT 1-8, *14) 512 Current Data, *15) 768 Current Data with Recall Safe, *16) 8192 Store Undo Data, 8193 Recall Undo Data, 8194 Clear Undo Data, *17) 0-199 Input CH Library Number (0 Request Only), *18) 0-199 Output CH Library Number (0 Request Only), *19) 512-527 Premium Rack 1A, 1B, 2A, ... 8A, 8B *20) 0-100 Each Premium Effect Library Number (0 Request Only) *21) 1536-1607 Input 1-64 (for Dynamics2), *22) 1608-1623 STIN 1L-8R (for Dunamics2), *23) 0-10 Dante Input Patch Library Number (0 Request Only) Data is lost when you write to the preset library. The unique header (Model ID) identifies whether the device is a QL series. To calculate the check sum, add the bytes starting with the byte after BYTE COUNT (LOW) and ending with the byte before CHECK SUM, take the binary complement, and set bit 7 to 0. CHECK SUM = (-sum)&0x7F Bulk Dumps can be received at any time, and can be transmitted at any time when a Bulk Dump Request is received. A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump Request. In the data portion, seven words of 8-bit data are converted into eight words of 7-bit data. 34 Data List

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264

Data List
34
2
SYSTEM REALTIME MESSAGE
2.1
SONG SELECT
(F3)
Reception
Select the track number shown in the TITLE LIST screen of the USB memory recorder.
2.2
TIMING CLOCK
(F8)
Reception
This message is used to control effects. This message is transmitted twenty-four
times per quarter note.
Echoing of this message depends on the OTHER item in the ECHO settings.
2.3
ACTIVE SENSING
(FE)
Reception
Once this message has been received, MIDI communication will be initialized (e.g.,
Running Status will be cleared) if no message is received for an interval of 400 ms.
This message is not subject to echoing.
2.4
SYSTEM RESET
(FF)
Reception
When this message is received, MIDI communication will be initialized (e.g.,
Running Status will be cleared).
This message is not subject to echoing.
3
SYSTEM EXCLUSIVE MESSAGE
3.1
MMC
< MMC STOP >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and stops.
< MMC PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
< MMC DEFERED PLAY >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message and starts playback.
< MMC RECORD STROBE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if stopped, starts
recording.
< MMC PAUSE >
Reception
If the [DEVICE NO.] matches or is 7F, receives this message, and if playing, pauses.
3.2
BULK DUMP
This message is used to send or receive the contents of various memories stored
within the unit.
The basic format is as follows.
The QL series console uses the following data types for a bulk dump.
*1)
0–300 Scene Number (0 Request Only),
*2)
1–199 Input EQ Library Number (1–40 Request Only)
*3)
1–199 Output EQ Library Number (1–3 Request Only)
*4)
1–199 Dynamics Library Number (1–41 Request Only)
*5)
0–199 GEQ Library Number (0 Request Only)
*6)
1–199 Effect Library Number (1–27 Request Only)
*7)
512–583 Input 1-64,
*8)
584–599 STIN 1L-8R,
*9)
768–791 MIX 1-16,
*10)
1024–1031 MATRIX 1-8,
*11)
1280–1282 STEREO L-C,
*12)
512–530 GEQ 1–19, 531–538 EFFECT GEQ 1–8,
*13)
512–519 EFFECT 1–8,
*14)
512 Current Data,
*15)
768 Current Data with Recall Safe,
*16)
8192 Store Undo Data, 8193 Recall Undo Data, 8194 Clear Undo Data,
*17)
0–199 Input CH Library Number (0 Request Only),
*18)
0–199 Output CH Library Number (0 Request Only),
*19)
512–527 Premium Rack 1A, 1B, 2A, ... 8A, 8B
*20)
0–100 Each Premium Effect Library Number (0 Request Only)
*21)
1536–1607 Input 1–64 (for Dynamics2),
*22)
1608–1623 STIN 1L–8R (for Dunamics2),
*23)
0-10 Dante Input Patch Library Number (0 Request Only)
Data is lost when you write to the preset library.
The unique header (Model ID) identifies whether the device is a QL series.
To calculate the check sum, add the bytes starting with the byte after BYTE
COUNT (LOW) and ending with the byte before CHECK SUM, take the binary
complement, and set bit 7 to 0.
CHECK SUM = (-sum)&0x7F
Bulk Dumps can be received at any time, and can be transmitted at any time
when a Bulk Dump Request is received.
A Bulk Dump is transmitted on the [Rx CH] channel in response to a Bulk Dump
Request.
In the data portion, seven words of 8-bit data are converted into eight words of
7-bit data.
STATUS
11110011 F3
Song select
Song number 0sssssss ss
Song number (0-127)
STATUS
11111000 F8
Timing clock
STATUS
11111110 FE
Active sensing
STATUS
11111111 FF
System reset
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000001 01
Stop(MCS)
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000010 02
Play(MCS)
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000011 03
Deferred Play(MCS)
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00000110 06
Record strobe
EOX
11110111 F7
End of exclusive
STATUS
11110000 F0
System exclusive message
ID No.
01111111 7F
Real time System exclusive
Device ID
0ddddddd dd
Destination (00-7E, 7F:all call)
COMMAND
00000110 06
Machine Control Command(MCC) sub-id
00001001 09
Pause(MCS)
EOX
11110111 F7
End of exclusive
Command
rx/tx
Function
F0 43 0n 3E cc cc 19 mm ... mm dd
dd ... ee F7
rx/tx
BULK DUMP DATA
F0 43 2n 3E 19 mm ... mm dd dd F7
rx
BULK DUMP REQUEST
Module Name(mm)
Data Number(dd)
SCENE LIB
“SCENE___”
*1) *14) *15) *16)
INPUT EQ LIB
“INEQ____”
*2) *7) *8)
OUTPUT EQ LIB
“OUTEQ___”
*3) *9) *10) *11)
Dynamics LIB
“DYNA____”
*4) *7) *8) *9) *10) *11) *21) *22)
INPUT CH LIB
“INCHNNL_”
*17) *7) *8)
OUTPUT CH LIB
“OUTCHNNL”
*18) *9) *10) *11)
GEQ LIB
“GEQ_____”
*5) *12)
EFFECT LIB
“EFFECT__”
*6) *13)
Premium Effect
“PEFFECT_”
*19)
Portico5033 LIB
“P5033___”
*20)
Portico5043 LIB
“P5043___”
*20)
U76 LIB
“U76_____”
*20)
Opt-2A LIB
“OPT-2A__”
*20)
EQP-1A LIB
“EQ-1A___”
*20)
DynamicEQ LIB
“DYNAEQ__”
*20)
Dante Input Patch LIB
“DANTEIN_”
*23)
Mixer Setup
“MIXERSET”
Fix (512)
Outport Setup
“OUT_PORT”
Fix (512)
Monitor Setup
“MONITOR_”
Fix (512)
MIDI Setup
“MIDI_SET”
Fix (512)
Lib Number
“LIB_NUM_”
Fix (512)
Program Change Table
“PRGMCHG_”
Fix (512)
Control Change Table
“CTRLCHG_”
Fix (512)
Preference (Current)
“PREF_CUR”
Fix (512)
Preference (Admin)
“PREF_ADM”
Fix (512)
Preference (Guest)
“PREF_GST”
Fix (512)
User Defined Keys (Current)
“UDEF_CUR”
Fix (512) include Knob, Encoder
User Defined Keys (Admin)
“UDEF_ADM”
Fix (512) include Knob, Encoder
User Defined Keys (Guest)
“UDEF_GST”
Fix (512) include Knob, Encoder
Custom Fader Bank (Current)
“CFAD_CUR”
Fix (512)
Custom Fader Bank (Admin)
“CFAD_ADM”
Fix (512)
Custom Fader Bank (Guest)
“CFAD_GST”
Fix (512)
User Level (Current)
“UKEY_CUR”
Fix (512)
User Level (Guest)
“UKEY_GST”
Fix (512)
Module Name(mm)
Data Number(dd)