Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 137

Table 5-4, Automatic Server Recovery-2 ASR-2 IML Messages

Page 137 highlights

Error Recovery The IML identifies and records all of the errors described in Table 5-4. Table 5-4: Automatic Server Recovery-2 (ASR-2) IML Messages Message Abnormal Program Termination ASR-2 detected by ROM ASR-2 Test Event ASR-2 Base Memory Parity Error ASR-2 Extended Memory Parity Error ASR-2 Memory Parity Error ASR-2 Reset Limit Reached Battery Failing Caution: Temperature Exceeded Diagnostic Error Error Detected On Boot Up Description The operating system encountered an abnormal situation that caused a system failure. An ASR-2 activity was detected and logged by the system ROM. The server setup utility generated a test alert. The system detected a data error in base memory following a reset, due to the ASR-2 timer expiration. The system detected a data error in extended memory following a reset, due to the ASR-2 timer expiration. The system ROM was unable to allocate enough memory to create a stack. It was then unable to display a message on the screen or continue booting the server. The maximum number of system resets due to ASR-2 timer expiration was reached, resulting in the loading of Diagnostics. This is a low system battery warning. Replace battery within seven days to prevent loss of nonvolatile configuration memory. Failure of the battery supporting the system nonvolatile RAM is imminent. The operating system detected that the temperature of the system exceeded the caution level. Accompanying data is in the log notes if an auto-shutdown sequence was invoked by the operating system. An error was detected by the Diagnostics. The server detected an error during the Power-On Self-Test (POST). continued 5-16 HP Servers Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

Error Recovery
5-16
HP Servers Troubleshooting Guide
The IML identifies and records all of the errors described in Table 5-4.
Table 5-4:
Automatic Server Recovery-2 (ASR-2) IML Messages
Message
Description
Abnormal Program
Termination
The operating system encountered an abnormal
situation that caused a system failure.
ASR-2 detected by
ROM
An ASR-2 activity was detected and logged by
the system ROM.
ASR-2 Test Event
The server setup utility generated a test alert.
ASR-2 Base Memory
Parity Error
The system detected a data error in base
memory following a reset, due to the ASR-2 timer
expiration.
ASR-2 Extended
Memory Parity Error
The system detected a data error in extended
memory following a reset, due to the ASR-2 timer
expiration.
ASR-2 Memory Parity
Error
The system ROM was unable to allocate enough
memory to create a stack. It was then unable to
display a message on the screen or continue
booting the server.
ASR-2 Reset Limit
Reached
The maximum number of system resets due to
ASR-2 timer expiration was reached, resulting in
the loading of Diagnostics.
Battery Failing
This is a low system battery warning. Replace
battery within seven days to prevent loss of
nonvolatile configuration memory. Failure of the
battery supporting the system nonvolatile RAM is
imminent.
Caution: Temperature
Exceeded
The operating system detected that the
temperature of the system exceeded the caution
level. Accompanying data is in the log notes if an
auto-shutdown sequence was invoked by the
operating system.
Diagnostic Error
An error was detected by the Diagnostics.
Error Detected On
Boot Up
The server detected an error during the
Power-On Self-Test (POST).
continued