Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 249

Write Error or Self, Select F1

Page 249 highlights

POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1797-Drive Array - Array Accelerator Read Error Occurred. Data in Array Accelerator has been lost. Array Accelerator is disabled. None Hard parity error detected while reading data from posted-writes memory. 1798-Drive Array - Array Accelerator Write Error or SelfTest Error Occurred. Array Accelerator is disabled. None Array accelerator failed self-test. Depending on the array controller model, the cache may be disabled or the controller might not be usable at all until this problem is corrected. 1799-Drive Array - Drive(s) Disabled due to Array Accelerator Data Loss. Select "F1" to continue with logical drives disabled. Select "F2" to accept data loss and to re-enable logical drives. None Logical drive(s) failed due to loss of data in posted-writes memory. Action Replace array accelerator daughter board. Replace array accelerator daughter board. Press the F1 key to continue with logical drive(s) disabled or the F2 key to accept data loss and re-enable logical drive(s). After pressing the F2 key, check integrity of file system and restore lost data from backup. HP Servers Troubleshooting Guide C-69

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

POST Error Messages
HP Servers Troubleshooting Guide
C-69
Table C-13:
1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1797-Drive Array –
Array Accelerator
Read Error Occurred.
Data in Array
Accelerator has been
lost.
Array Accelerator is
disabled.
None
Hard parity error detected
while reading data from
posted-writes memory.
Replace array accelerator
daughter board.
1798-Drive Array –
Array Accelerator
Write Error or Self-
Test Error Occurred.
Array Accelerator is
disabled.
None
Array accelerator failed
self-test. Depending on
the array controller
model, the cache may be
disabled or the controller
might not be usable at all
until this problem is
corrected.
Replace array accelerator
daughter board.
1799-Drive Array –
Drive(s) Disabled due
to Array Accelerator
Data Loss.
Select “F1” to
continue with logical
drives disabled.
Select “F2” to accept
data loss and to
re-enable logical
drives.
None
Logical drive(s) failed due
to loss of data in
posted-writes memory.
Press the
F1
key to continue
with logical drive(s) disabled
or the
F2
key to accept data
loss and re-enable logical
drive(s). After pressing the
F2
key, check integrity of file
system and restore lost data
from backup.