Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 228
Array - RAID ADG, the Array Accelerator
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 228 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1705-Locked SCSI Bus Detected None A SCSI controller cannot communicate with devices connected to a SCSI bus. 1711-Slot z Drive Array - RAID ADG logical drive(s) configured but Array Accelerator size
POST Error Messages
C-48
HP Servers Troubleshooting Guide
Table C-13:
1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1705-Locked SCSI
Bus Detected
None
A SCSI controller cannot
communicate with
devices connected to a
SCSI bus.
1.
Check the SCSI cable
installation.
2.
Be sure that the SCSI
cable has proper
termination.
1711-Slot z Drive
Array - RAID ADG
logical drive(s)
configured but Array
Accelerator size
<= 32 MB. This
configuration is not
recommended.
Consider migrating
logical drive(s) to
RAID 5 or upgrading
the Array Accelerator
module.
None
Configuration not
recommended.
Migrate logical drive(s) to
RAID 5 or upgrade to a larger
array accelerator module.
1712-Slot z Drive
Array - RAID 5 logical
drive(s) configured
with 56 drives, but
Array Accelerator size
<= 32 MB. This
configuration is not
recommended.
Consider migrating
logical drive(s) to
RAID 0 or 1, reducing
the number of drives
in the array, or
upgrading the Array
Accelerator module.
None
Configuration not
recommended.
Migrate logical drive(s) to
RAID 0 or 1, reduce the
number of drives in the array,
or upgrade to a larger-size
array accelerator module.
continued