PCI Hot Plug enabler is, Supply Fan Failure
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 223 highlights
POST Error Messages Table C-12: 1600 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1615- Power Supply Failure None Power supply has failed. 1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan Failure in Bay X. 1616- Power Supply Configuration Failure 1617-Fan controller not responding 1617-Fan controller not responding. System halted. 1617-I/O Fan controller not responding. System halted. 1617-CPU Fan controller not responding. System halted. 1618-PCI slots powered down. Check PCI Hot-Plug enabler connectors. 1618- PCI slots powered down. None None 2 short 2 short 2 short 2 short None None Power supply has failed. Power supply is improperly configured. Fan controller failure detected. Fan controller failure detected. I/O fan controller failure detected. CPU fan controller failure detected. PCI Hot Plug enabler is missing or failed. PCI Hot plug enabler is missing or failed. Action Reseat power supply firmly. -OrReplace power supply as soon as possible. Reseat power supply firmly. -OrReplace power supply as soon as possible. Run the server setup utility and correct. Check and replace failed controller assembly. Check and replace failed controller assembly. Check and replace failed controller assembly. Check and replace failed controller assembly. Check and replace missing or failed assembly. Check and replace missing or failed assembly. continued HP Servers Troubleshooting Guide C-43