Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 252

Table D-1, Array Diagnostic Utility ADU Error Messages, Message, Description, Recommended Action

Page 252 highlights

ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages Message Accelerator board not detected Accelerator error log Accelerator parity read errors: X Accelerator parity write errors: X Accelerator status: Cache was automatically configured during last controller reset Accelerator status: Data in the cache was lost due to some reason other than the battery being discharged. Description Array controller did not detect a configured array accelerator board. List of the last 32 parity errors on transfers to or from the memory on the array accelerator board. Displays starting memory address, transfer count, and operation (read and write). Number of times that read memory parity errors were detected during transfers from memory on array accelerator board. Number of times that write memory parity errors were detected during transfers to memory on the array accelerator board. Cache board was replaced with one of a different size. Data in cache was lost, but not because of the battery being discharged. Recommended Action Install an array accelerator board on an array controller. If an array accelerator board is installed, check for proper seating on the array controller board. If there are many parity errors, you may need to replace the array accelerator board. If there are many parity errors, you may need to replace the array accelerator board. If there are many parity errors, you may need to replace the array accelerator board. Normal operations should continue. Check to be sure that the array accelerator is properly seated. If the error continues, you may need to replace the array accelerator. continued D-2 HP Servers Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

ADU Error Messages
D-2
HP Servers Troubleshooting Guide
Table D-1:
Array Diagnostic Utility (ADU) Error Messages
Message
Description
Recommended Action
Accelerator board not detected
Array controller did not detect
a configured array accelerator
board.
Install an array accelerator
board on an array controller. If
an array accelerator board is
installed, check for proper
seating on the array controller
board.
Accelerator error log
List of the last 32 parity errors
on transfers to or from the
memory on the array
accelerator board. Displays
starting memory address,
transfer count, and operation
(read and write).
If there are many parity errors,
you may need to replace the
array accelerator board.
Accelerator parity read errors:
X
Number of times that read
memory parity errors were
detected during transfers from
memory on array accelerator
board.
If there are many parity errors,
you may need to replace the
array accelerator board.
Accelerator parity write errors:
X
Number of times that write
memory parity errors were
detected during transfers to
memory on the array
accelerator board.
If there are many parity errors,
you may need to replace the
array accelerator board.
Accelerator status: Cache was
automatically configured
during last controller reset
Cache board was replaced
with one of a different size.
Normal operations should
continue.
Accelerator status: Data in the
cache was lost due to some
reason other than the battery
being discharged.
Data in cache was lost, but not
because of the battery being
discharged.
Check to be sure that the array
accelerator is properly seated.
If the error continues, you may
need to replace the array
accelerator.
continued