Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 270

SOLUTION: Power down, locations, and then refer

Page 270 highlights

ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Swapped cables or Configuration error detected. A drive rearrangement was attempted while an expand operation was running. This is an unsupported operation. SOLUTION: Power down system then move drives back to their original location. Power on system and wait for the expand operation to complete before attempting a drive rearrangement. One or more drive locations were changed while an expand operation was in progress. 1. Power down the server. 2. Place the drives in their original locations. 3. Restart the server, and then complete the expand operation. 4. Move the drives to their new locations after the expand operation is completed. Swapped cables or Configuration error detected. An unsupported drive arrangement was attempted. SOLUTION: Power down system then move drives back to their original location. One or more physical drives were moved, causing a configuration that is not supported. Move all drives to their original locations, and then refer to your server-specific user documentation for supported configurations. Swapped cables or Configuration error detected. The cables appear to be interchanged. SOLUTION: Power down system then move the drives or cables back to their original location. ADU has detected a change in the cable configuration. One or more cables may be connected to the incorrect bus. -Or- One or more drives have been moved to new locations. Refer to your server-specific user documentation for supported configurations and cabling guidelines. Restore to the original configuration. continued D-20 HP Servers Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

ADU Error Messages
D-20
HP Servers Troubleshooting Guide
Table D-1:
Array Diagnostic Utility (ADU) Error Messages
continued
Message
Description
Recommended Action
Swapped cables or
Configuration error detected. A
drive rearrangement was
attempted while an expand
operation was running. This is
an unsupported operation.
SOLUTION: Power down
system then move drives back
to their original location. Power
on system and wait for the
expand operation to complete
before attempting a drive
rearrangement.
One or more drive locations
were changed while an
expand operation was in
progress.
1.
Power down the server.
2.
Place the drives in their
original locations.
3.
Restart the server, and
then complete the expand
operation.
4.
Move the drives to their
new locations after the
expand operation is
completed.
Swapped cables or
Configuration error detected.
An unsupported drive
arrangement was attempted.
SOLUTION: Power down
system then move drives back
to their original location.
One or more physical drives
were moved, causing a
configuration that is not
supported.
Move all drives to their original
locations, and then refer to
your server-specific user
documentation for supported
configurations.
Swapped cables or
Configuration error detected.
The cables appear to be
interchanged.
SOLUTION: Power down
system then move the drives
or cables back to their original
location.
ADU has detected a change in
the cable configuration.
One or more cables may be
connected to the incorrect bus.
-Or-
One or more drives have been
moved to new locations.
Refer to your server-specific
user documentation for
supported configurations and
cabling guidelines.
Restore to the original
configuration.
continued