Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 270
SOLUTION: Power down, locations, and then refer
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 270 highlights
ADU Error Messages Table D-1: Array Diagnostic Utility (ADU) Error Messages continued Message Description Recommended Action Swapped cables or Configuration error detected. A drive rearrangement was attempted while an expand operation was running. This is an unsupported operation. SOLUTION: Power down system then move drives back to their original location. Power on system and wait for the expand operation to complete before attempting a drive rearrangement. One or more drive locations were changed while an expand operation was in progress. 1. Power down the server. 2. Place the drives in their original locations. 3. Restart the server, and then complete the expand operation. 4. Move the drives to their new locations after the expand operation is completed. Swapped cables or Configuration error detected. An unsupported drive arrangement was attempted. SOLUTION: Power down system then move drives back to their original location. One or more physical drives were moved, causing a configuration that is not supported. Move all drives to their original locations, and then refer to your server-specific user documentation for supported configurations. Swapped cables or Configuration error detected. The cables appear to be interchanged. SOLUTION: Power down system then move the drives or cables back to their original location. ADU has detected a change in the cable configuration. One or more cables may be connected to the incorrect bus. -Or- One or more drives have been moved to new locations. Refer to your server-specific user documentation for supported configurations and cabling guidelines. Restore to the original configuration. continued D-20 HP Servers Troubleshooting Guide