Hardware Problems Table 2-6: Memory Problems continued Problem Possible Cause Memory count error occurs. Server fails to recognize new memory. There may be a conflict with existing memory. Server fails to recognize Memory may not be new memory (continued). installed properly. The memory installed may not be compatible with your server or may have exceeded limits set for the server or operating system. Memory may have failed. Possible Solution 1. Be sure that the memory modules have been installed correctly. Refer to your server-specific user documentation. 2. Be sure that the memory modules are properly seated. 3. Run the server setup utility. 4. Restart the server. If the POST count is still wrong, replace the memory. 1. Check the IML. 2. Check for conflicts with existing memory. 3. Run the server setup utility. 1. Be sure that the memory is properly seated. 2. Be sure that the memory modules have been installed correctly. Refer to your server-specific user documentation. 1. Be sure that the memory installed is the correct type of memory for your server. 2. Be sure that you have not exceeded the memory limits of the server or operating system. Check the appropriate documentation. 1. Test by installing memory into a working server. 2. Replace the memory. Refer to the procedures in your server user documentation. HP Servers Troubleshooting Guide 2-19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

Hardware Problems
HP Servers Troubleshooting Guide
2-19
Table 2-6:
Memory Problems
continued
Problem
Possible Cause
Possible Solution
Memory count error
occurs.
1.
Be sure that the memory modules
have been installed correctly. Refer
to your server-specific user
documentation.
2.
Be sure that the memory modules
are properly seated.
3.
Run the server setup utility.
4.
Restart the server. If the POST
count is still wrong, replace the
memory.
Server fails to recognize
new memory.
There may be a conflict
with existing memory.
1.
Check the IML.
2.
Check for conflicts with existing
memory.
3.
Run the server setup utility.
Server fails to recognize
new memory (
continued
).
Memory may not be
installed properly.
1.
Be sure that the memory is properly
seated.
2.
Be sure that the memory modules
have been installed correctly. Refer
to your server-specific user
documentation.
The memory installed
may not be compatible
with your server or may
have exceeded limits set
for the server or
operating system.
1.
Be sure that the memory installed is
the correct type of memory for your
server.
2.
Be sure that you have not exceeded
the memory limits of the server or
operating system. Check the
appropriate documentation.
Memory may have failed.
1.
Test by installing memory into a
working server.
2.
Replace the memory. Refer to the
procedures in your server user
documentation.