Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 198
Speed - Check DIMM, DIMM Socket X does
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 198 highlights
POST Error Messages Table C-4: 200 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 207-Invalid Memory None Configuration, Bank X A memory bank has been incorrectly populated. 207- Memory Installation Error None 207-Memory Configuration Warning - DIMM in DIMM Socket X does not have Primary Width of 4 and only supports standard ECC. 208-Invalid Memory Speed - Check DIMM Installation 1 long, 1 short, or none 1 long, 1 short Memory module installed incorrectly or unsupported DIMM. Installed DIMMs have a primary width of x8. The speed of the memory is not compatible. 209-Memory Detection Failure. Check Memory Installation. 209-Online Spare Memory Configuration - Bank A does not match Bank C. 1 long, 1 short 1 long, 1 short Unable to size memory. DIMM group mismatch between Bank A and Bank C. Action Check the location of the bank specified. This bank number will correspond to the bank number shown on the memory expansion board identification label located on the top air baffle of the processor/memory drawer. Check that a bank has been populated with four DIMMs of the same type, size, and speed. Check placement of memory modules. Install DIMMs that have a primary width of x4. Check the speed of the memory modules installed. Then, check your server user documentation and replace as indicated. Check memory module installation. Check for additional resources at www.hp.com. Check the size and speed of the memory modules installed. Then, check your server user documentation and replace as indicated. continued C-18 HP Servers Troubleshooting Guide