Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 248

the Array Configuration Utility, Array Accelerator is

Page 248 highlights

POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1794-Drive Array - Array Accelerator Battery Charge Low. Array Accelerator is temporarily disabled. None This is a warning that the battery charge is below 75 percent. Posted writes are disabled. Array Accelerator will be re-enabled when battery reaches full charge. Action Replace the array accelerator board if batteries do not recharge within 36 power-on hours. 1795-Drive Array - Array Accelerator Configuration Error. Data does not correspond to this drive array. Array Accelerator is temporarily disabled. None 1796-Drive Array - Array Accelerator Not Responding. Array Accelerator is temporarily disabled. None This indicates that while the system was in use, power was interrupted while data was in the array accelerator memory. The data stored in the array accelerator does not correspond to this drive array. Array accelerator is defective or has been removed. Depending on the array controller model, the cache may be disabled or the controller might not be usable at all until this problem is corrected. Match the array accelerator to the correct drive array, or run the Array Configuration Utility to clear the data in the array accelerator. Replace array accelerator daughter board, or reseat if connector has become loose. continued C-68 HP Servers Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

POST Error Messages
C-68
HP Servers Troubleshooting Guide
Table C-13:
1700 Series POST Error Messages
continued
Error Code
Audible
Beeps
Probable Source of
Problem
Action
1794-Drive Array –
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
None
This is a warning that the
battery charge is below
75 percent. Posted writes
are disabled.
Replace the array accelerator
board if batteries do not
recharge within 36 power-on
hours.
1795-Drive Array –
Array Accelerator
Configuration Error
.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
array accelerator
memory.
The data stored in the
array accelerator does
not correspond to this
drive array.
Match the array accelerator to
the correct drive array, or run
the Array Configuration Utility
to clear the data in the array
accelerator.
1796-Drive Array –
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
None
Array accelerator is
defective or has been
removed. Depending on
the array controller
model, the cache may be
disabled or the controller
might not be usable at all
until this problem is
corrected.
Replace array accelerator
daughter board, or reseat if
connector has become loose.
continued