Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 248
the Array Configuration Utility, Array Accelerator is
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 248 highlights
POST Error Messages Table C-13: 1700 Series POST Error Messages continued Error Code Audible Beeps Probable Source of Problem 1794-Drive Array - Array Accelerator Battery Charge Low. Array Accelerator is temporarily disabled. None This is a warning that the battery charge is below 75 percent. Posted writes are disabled. Array Accelerator will be re-enabled when battery reaches full charge. Action Replace the array accelerator board if batteries do not recharge within 36 power-on hours. 1795-Drive Array - Array Accelerator Configuration Error. Data does not correspond to this drive array. Array Accelerator is temporarily disabled. None 1796-Drive Array - Array Accelerator Not Responding. Array Accelerator is temporarily disabled. None This indicates that while the system was in use, power was interrupted while data was in the array accelerator memory. The data stored in the array accelerator does not correspond to this drive array. Array accelerator is defective or has been removed. Depending on the array controller model, the cache may be disabled or the controller might not be usable at all until this problem is corrected. Match the array accelerator to the correct drive array, or run the Array Configuration Utility to clear the data in the array accelerator. Replace array accelerator daughter board, or reseat if connector has become loose. continued C-68 HP Servers Troubleshooting Guide