Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 186
in Hot-Plug PCI Slot X, System ROM
View all Compaq ProLiant 1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 186 highlights
POST Error Messages Table C-2: Non-Numeric Error Messages or Beeps Only continued Error Code Audible Beeps Probable Source of Problem Action Power Fault Detected 2 short in Hot-Plug PCI Slot X PCI-X Hot Plug expansion slot was not powered up properly. Reboot the server. Processor in incorrect socket. - System Halted!. None Processor is installed in socket 2 only. Install processor in socket 1. Processor packages do not match.. 1 long, 1 short Installed processors are different types. Install processors of the same type. Please make sure that all processor packages are the same. - System Halted! REDUNDANT ROM ERROR: Backup ROM invalid. - run ROMPAQ to correct error condition. None System ROM and redundant ROM are both corrupt. Run ROMPaq Utility. REDUNDANT ROM ERROR: Bootblock invalid. - contact COMPAQ Representative. None ROM bootblock is corrupt. Contact authorized service provider. RESUME - F1 key None As indicated to continue. Press the F1 key. (Run System Configuration Utility - F10 key) None A configuration error occurred during POST. Press the F10 key to run server setup utility. Unsupported Processor Detected System Halted. 1 long, 1 short Processor not supported by current system ROM. Check documentation for supported processors. If supported, remove the processor and update system to latest ROM. continued C-6 HP Servers Troubleshooting Guide