Compaq ProLiant 1000 ProLiant Server Troubleshooting Guide - Page 210

Series POST Error Messages, Install the Server Feature

Page 210 highlights

POST Error Messages 800 Series POST Error Messages Table C-9: 800 Series POST Error Messages Error Code 800-Server Feature Board must be installed in slot 1 for proper operation Audible Beeps None 801-Server Feature Board is not properly cabled to the system. Verify that the server management information cable from the system board to the Server Feature Board in slot 1 is intact and fully secured at both ends None Probable Source of Problem The system has detected the absence of the Server Feature Board. The Server Feature Board is not installed in the proper slot. The Server Feature Board does not match this system. The system has detected that the servermanagement information cable is not properly installed. Action 1. Install the Server Feature Board in PCI slot 1. 2. Reseat the Server Feature Board. 3. Be sure that the Server Feature Board is from this system. 1. Be sure that a servermanagement information cable is installed in the system. 2. Inspect the servermanagement information cable for signs of damage. 3. Reseat the servermanagement information cable on the system board and on the Server Feature Board. continued C-30 HP Servers Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254
  • 255
  • 256
  • 257
  • 258
  • 259
  • 260
  • 261
  • 262
  • 263
  • 264
  • 265
  • 266
  • 267
  • 268
  • 269
  • 270
  • 271
  • 272
  • 273
  • 274
  • 275
  • 276
  • 277
  • 278
  • 279
  • 280
  • 281
  • 282
  • 283
  • 284
  • 285
  • 286
  • 287
  • 288
  • 289
  • 290
  • 291
  • 292
  • 293
  • 294
  • 295
  • 296
  • 297
  • 298
  • 299
  • 300
  • 301
  • 302
  • 303
  • 304
  • 305
  • 306
  • 307

POST Error Messages
C-30
HP Servers Troubleshooting Guide
800 Series POST Error Messages
Table C-9:
800 Series POST Error Messages
Error Code
Audible
Beeps
Probable Source of
Problem
Action
800-Server Feature
Board must be
installed in slot 1 for
proper operation
None
The system has detected
the absence of the
Server Feature Board.
The Server Feature
Board is not installed in
the proper slot.
The Server Feature
Board does not match
this system.
1.
Install the Server Feature
Board in PCI slot 1.
2.
Reseat the Server
Feature Board.
3.
Be sure that the Server
Feature Board is from
this system.
801-Server Feature
Board is not properly
cabled to the system.
Verify that the server
management
information cable from
the system board to
the Server Feature
Board in slot 1 is
intact and fully
secured at both ends
None
The system has detected
that the server-
management information
cable is not properly
installed.
1.
Be sure that a server-
management information
cable is installed in the
system.
2.
Inspect the server-
management information
cable for signs of
damage.
3.
Reseat the server-
management information
cable on the system
board and on the Server
Feature Board.
continued