Dell PowerEdge T605 Hardware Owner's Manual (PDF) - Page 28
E1A15 SAS Cable D, E1A18 PDB Ctrl, Cable, E1A19 12V Cable, Fault, E1B01 USB, Overcurrent, E2010 No - memory configuration
View all Dell PowerEdge T605 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 28 highlights
Table 1-5. LCD Status Messages (continued) Code Text E1A15 SAS Cable D E1A18 PDB Ctrl Cable E1A19 12V Cable Fault E1B01 USB# Overcurrent E2010 No Memory E2011 Mem Config Err E2012 Unusable Memory Causes Corrective Actions SAS cable D is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 205. Control cable for the power Reseat the cable. If the distribution board (PDB) is problem persists, replace missing or bad. cable. If the problem persists, see "Getting Help" on page 205. Power cable for the PDB or Reseat the cable. If the cabled power supply is problem persists, replace missing or bad. They system cable. will not turn on. If the problem persists, see "Getting Help" on page 205. Device plugged in the specified USB port caused an overcurrent condition. Reseat the device cable. If the problem persists, replace or remove the device. No memory is installed in the system. Install memory (see "Installing Memory Modules" on page 130). Memory detected, but is not See "Troubleshooting configurable. Error detected System Memory" on during memory page 174. configuration. Memory is configured, but See "Troubleshooting not usable. Memory System Memory" on subsystem failure. page 174. 28 About Your System