Dell PowerEdge T605 Hardware Owner's Manual (PDF) - Page 33

Corrective Actions, Product, Information Guide

Page 33 highlights

CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the components inside the system. See your Product Information Guide for complete information about safety precautions, working inside the system, and protecting against electrostatic discharge. Table 1-6. System Messages Message Causes Corrective Actions Alert! Redundant memory disabled! Memory configuration does not support redundant memory. Redundant memory was set to enable in CMOS, but the current configuration does not support redundant memory. See "General Memory Module Installation Guidelines" on page 127 for memory configuration information. If the problem persists, see "Troubleshooting System Memory" on page 174. Alert! Redundancy was previously lost. Power cycle required to reconfigure redundant memory. A spare rank event occurred during the previous boot. See "General Memory Module Installation Guidelines" on page 127 for memory configuration information. If the problem persists, see "Troubleshooting System Memory" on page 174. Attempting to update Remote Configuration. Please wait... Remote Configuration request has been detected and is being processed. Wait until the process is complete. BIOS Update Remote BIOS update Attempt Failed! attempt failed. Retry the BIOS update. If problem persists, see "Getting Help" on page 205. Caution! NVRAM_CLR jumper is installed on system board. NVRAM_CLR jumper is installed. CMOS has been cleared. Remove NVRAM_CLR jumper (see Figure 6-1 for jumper location). Decreasing Faulty or improperly installed See "Troubleshooting System available memory memory modules. Memory" on page 174. About Your System 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230

About Your System
33
CAUTION:
Only trained service technicians are authorized to remove the system
cover and access any of the components inside the system. See your
Product
Information Guide
for complete information about safety precautions, working
inside the system, and protecting against electrostatic discharge.
Table 1-6.
System Messages
Message
Causes
Corrective Actions
Alert! Redundant
memory disabled!
Memory
configuration
does not support
redundant
memory.
Redundant memory was set
to enable in CMOS, but the
current configuration does
not support redundant
memory.
See "General Memory
Module Installation
Guidelines" on page 127 for
memory configuration
information. If the problem
persists, see
"Troubleshooting System
Memory" on page 174.
Alert!
Redundancy was
previously lost.
Power cycle
required to
reconfigure
redundant
memory.
A spare rank event occurred
during the previous boot.
See "General Memory
Module Installation
Guidelines" on page 127 for
memory configuration
information. If the problem
persists, see
"Troubleshooting System
Memory" on page 174.
Attempting to
update Remote
Configuration.
Please wait...
Remote Configuration
request has been detected
and is being processed.
Wait until the process is
complete.
BIOS Update
Attempt Failed!
Remote BIOS update
attempt failed.
Retry the BIOS update. If
problem persists, see
"Getting Help" on page 205.
Caution!
NVRAM_CLR jumper
is installed on
system board.
NVRAM_CLR jumper is
installed. CMOS has been
cleared.
Remove NVRAM_CLR
jumper (see Figure 6-1 for
jumper location).
Decreasing
available memory
Faulty or improperly installed
memory modules.
See "Troubleshooting System
Memory" on page 174.