Dell PowerEdge T605 Hardware Owner's Manual (PDF) - Page 39
pending. Press I, Check the Time and Date
View all Dell PowerEdge T605 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions This system supports only Opteron(TM) 2000 series processors Microprocessor(s) is not supported by the system. Install a supported microprocessor or microprocessor combination (see "Installing a Processor" on page 136). Time-of-day clock stopped Faulty battery or faulty chip. See "Troubleshooting the System Battery" on page 170. Time-of-day not Incorrect Time or Date set - please run settings; faulty system SETUP program battery. Check the Time and Date settings (see "Entering the System Setup Program" on page 43). If the problem persists, replace the system battery (see "System Battery" on page 138). Timer chip Faulty system board. counter 2 failed See "Getting Help" on page 205. TPM configuration operation honored System will now restart. Information only. TPM failure A Trusted Platform Module See "Getting Help" on (TPM) function has failed. page 205. TPM operation is Configuration change has pending. Press I been requested. to Ignore or M to Modify to allow this change and reset the system. Press I to continue system boot. Press M to modify the TPM setting and restart. Unexpected interrupt in protected mode DIMMs are improperly Reseat the DIMMs (see seated or the keyboard/mouse "Troubleshooting System controller chip has failed. Memory" on page 174). If the problem persists, see "Getting Help" on page 205. About Your System 39