Plug & Play, reset: Slot X - install disks
View all Dell PowerEdge T605 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions PCIe Fatal Error caused a system reset: Slot X Embedded Bus#XX/Dev#XX/Fu ncX PCI Express fatal errors Reseat the PCIe card in the occurred during the previous specified slot number (see boot. "Installing an Expansion Card" on page 110). If the problem persists, see "Getting Help" on page 205. Please check the system event log for details Plug & Play Configuration Error Error encountered in initializing PCIe device; faulty system board. Install the NVRAM_CLR jumper and restart the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting Expansion Cards" on page 187. Read fault Requested sector not found The operating system cannot Replace the USB medium or read from the hard drive or device. Ensure that the USB USB device, the system could or hard drive cables are not find a particular sector on properly connected. See the disk, or the requested "Troubleshooting a USB sector is defective. Device" on page 165, or "Troubleshooting a Hard Drive" on page 181 for the appropriate drive(s) installed in your system. Remote configuration update attempt failed System unable to process Remote Configuration request. Retry Remote Configuration. About Your System 37