Dell PowerEdge T605 Hardware Owner's Manual (PDF) - Page 38
See Troubleshooting a Hard
View all Dell PowerEdge T605 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Table 1-6. System Messages (continued) Message Causes Corrective Actions ROM bad checksum Expansion card improperly = address installed or faulty. Reseat the expansion card(s). Ensure that all appropriate cables are securely connected to the expansion card(s). If the problem persists, see "Troubleshooting Expansion Cards" on page 187. SATA PORT x drive not found SATA port x was turned on in See "Troubleshooting a Hard setup, but a drive was not Drive" on page 181 for the found. appropriate drive(s) installed in your system. Sector not found Faulty hard drive, USB Seek error device, or USB medium. Seek operation failed See "Troubleshooting a USB Device" on page 165 or "Troubleshooting a Hard Drive" on page 181 for the appropriate drive(s) installed in your system. Shutdown failure Shutdown test failure. See "Troubleshooting System Memory" on page 174. Spare bank enabled DIMM sparing has been enabled. Information only. The amount of Memory has been added or system memory has removed or a memory changed module may be faulty. If memory has been added or removed, this message is informative and can be ignored. If memory has not been added or removed, check the SEL to determine if single-bit or multi-bit errors were detected and replace the faulty memory module (see "Troubleshooting System Memory" on page 174). 38 About Your System