Yamaha DSP5D Owner's Manual - Page 161
Adjusting the faders and input/output gain (Calibration), Calibrating the faders
View all Yamaha DSP5D manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 161 highlights
Adjusting the faders and input/output gain (Calibration) Depending on the conditions of use, discrepancies may occur in the behavior of the motor faders. you can use the Calibration function to correct such discrepancies. If necessary, you can also make fine adjustments to the analog input/output gain. 1 While holding down the [ENTER] key of the panel, turn on the power of the PW800W power supply. After the opening screen, the following calibration menu screen will appear. Calibrating the faders Here you can execute a semi-automatic procedure for calibrating the faders of the specified channel strip (INPUT, DCA, STEREO A/B, ST IN/FX RTN). This window will also appear if a problem with the fader settings is detected when the PM5D is started up. 2 Click one of the following buttons to choose what you want to calibrate. A window for the calibration item you selected will appear. CALIBRATE FADER POSITION The FADER CALIBRATION window will appear, allowing you to calibrate the specified faders. CALIBRATE AD INPUT GAIN (make fine adjustments to the analog input gain; PM5D-RH model only) The AD INPUT TRIM window will appear, allowing you to make fine adjustments to the gain of the specified analog input port. CALIBRATE OUTPUT GAIN (make fine adjustments to the output ports) The OUTPUT TRIM window will appear, allowing you to make fine adjustments to the gain of the specified output port. 3 Make calibration settings as directed by the instructions that appear in the window. 4 Click the OK button in the window. The calibration settings will be applied, and the PM5D will start up in normal mode. 1 Click a fader select button to add a check mark to the faders you want to calibrate. If problems with certain faders were detected during start-up, those buttons will be on (green), and check marks will already be shown for them. 2 Click the START CALIBRATION button; calibration will begin automatically. A progress bar will indicate the state of the process. 3 The automatic processing will end when the progress bar reaches 60%. Manually move all faders you specified for calibration to the positions listed below in the following order: 1 -∞ 2 -20 dB 3 0 dB 4 +10 dB 4 After you have set the faders to the correct position, press the [ENTER] key. Processing will proceed to the next fader position. 5 Repeat steps 3-4 for each fader position 1-4. 6 Verify that calibration has been completed and that all fader select buttons are now off. Then click the OK button. The calibration settings will be stored in internal memory. If a fader select button remains on (green), calibration has failed. Try executing calibration once again. Note The progress bar will indicate "Writing..." while the settings are being written to internal memory; do not turn off the power while this indication is visible. Other functions 19 PM5D/PM5D-RH V2 / DSP5D Owner's Manual Operating section 161