HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.1.x administrator guide (5697 - Page 401
Persistent DisableON ON ON
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 401 highlights
3. Enter the portCfgShow command to verify the port is persistently enabled as shown below: switch:admin06> portcfgpersistentenable 8/16 switch:admin06> portcfgpersistentenable 8/17 switch:admin06> portcfgpersistentenable 8/18 switch:admin06> portcfgpersistentenable 8/19 switch:admin06> portcfgshow Ports of Slot 8 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port ISL R_RDY Mode RSCN Suppressed Persistent DisableON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON EX Port Mirror Port Ports of Slot 8 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 Speed AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN AN Trunk Port ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON Long Distance VC Link Init Locked L_Port Locked G_Port Disabled E_Port ISL R_RDY Mode RSCN Suppressed Persistent Disable.. .. .. .. ON ON ON ON ON ON ON ON ON ON ON ON NPIV capability ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON ON EX Port switch:admin06> where AN:AutoNegotiate, ..:OFF, ??:INVALID. LM:L0.5 Fabric OS 6.1.x administrator guide 401