56-0000590-01 Rev A s cal e: 5/ 16" = 1" ! ge7 ge6 ge5 ge4 GE ge3 ge2 ge1 ge0 7 6 5 4 FC 3 2 1 0 ge7 G bE ports ge0 7 F C ports 0 FC4 16IP 40. 1 Figure 39 HP StorageWorks B-Series iSCSI Director Blade ports Enabling the iSCSI gateway service The iSCSI gateway service translates and directs SCSI traffic between an iSCSI initiator and an FC target. This procedure explains how to enable the iSCSI gateway service on the HP StorageWorks 4/256 SAN Director. 1. Connect and log in to the switch. 2. Enter the fosConfig --show command to show the current Fabric OS configuration. switch:admin> fosconfig --show FC Routing service:disabled iSCSI service:disabled iSNS Client service: disabled 3. Enter the fosConfig --enable command to enable the iSCSI gateway service. switch:admin> fosconfig --enable iscsi iSCSI service is enabled 4. Verify that the iSCSI gateway service is enabled. switch:admin> fosconfig --show FC Routing service:disabled iSCSI service:enabled Fabric OS 6.2 administrator guide 309