HP StorageWorks 8/80 HP StorageWorks Fabric OS 6.2 administrator guide (5697-0 - Page 359
zone --create -t ti TI_Zone1 -p 4,8; 4,5, 1,-1; 6,-1, zone --show, cfgactvshow, cfgenable cfg_TI
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 359 highlights
NOTE: In the following procedure the three TI zones in the edge and backbone fabrics are all given the same name, TI_Zone1. It is not required that the TI zones have the same name; this is done to avoid confusion. If several dedicated paths are set up across the FC router, the TI zones for each path can have the same name. 1. In each edge fabric, set up an LSAN zone that includes Host 1, Target 1, and Target 2, so these devices can communicate with each other. See Chapter 17, "Using the FC-FC routing service" on page 367 for information about creating LSAN zones. 2. Log in to edge fabric 1 and set up the TI zone. a. Enter the fabricShow command to display the switches in the fabric. From the output, you can determine the front and translate domains. E1switch:admin> fabricshow Switch ID Worldwide Name Enet IP Addr FC IP Addr Name 1: fffc01 50:00:51:e3:95:36:7e:04 0.0.0.0 0.0.0.0 "fcr_fd_1" 4: fffc04 10:00:00:60:69:80:1d:bc 10.32.72.4 0.0.0.0 >"E1switch" 6: fffc06 50:00:51:e3:95:48:9f:a0 0.0.0.0 0.0.0.0 "fcr_xd_6_9" The Fabric has 3 switches b. Enter the following commands to create and display a TI zone: E1switch:admin> zone --create -t ti TI_Zone1 -p "4,8; 4,5, 1,-1; 6,-1" E1switch:admin> zone --show Defined TI zone configuration: TI Zone Name: TI_Zone1 Port List: 4,8; 4,5; 1,-1; 6,-1 Status: Activated Failover: Enabled c. Enter the following commands to reactivate your current effective configuration and enforce the TI zones. E1switch:admin> cfgactvshow Effective configuration: cfg: cfg_TI zone: lsan_t_i_TI_Zone1 10:00:00:00:00:00:02:00:00 10:00:00:00:00:00:03:00:00 10:00:00:00:00:00:08:00:00 E1switch:admin> cfgenable cfg_TI You are about to enable a new zoning configuration. This action will replace the old zoning configuration with the current configuration selected. If the update includes changes to one or more traffic isolation zones, the update may result in localized disruption to traffic on ports associated with the traffic isolation zone changes Do you want to enable 'cfg_TI' configuration (yes, y, no, n): [no] y zone config "cfg_TI" is in effect Updating flash ... Fabric OS 6.2 administrator guide 357