Preventing Operation of a CrossPoint Button Row (Protect Function) You can temporarily prevent button operations for each cross-point button row on the cross-point control block. To enable/disable the protect function, use the following buttons. • ICP-X7000: [ROW-1 PROT] button to [ROW-4 PROT] button assigned to the cross-point pad • ICP-X1000 series: [PROT] button in the 1st row to 4th row assigned to the function button section To protect a cross-point button row Press the [ROW-1 PROT] button to [ROW-4 PROT] button/[PROT] button, turning it on, for the target crosspoint button row (1st row to 4th row) to set. To release the protection setting for a crosspoint button row Press the [ROW-1 PROT] button to [ROW-4 PROT] button/[PROT] button, turning it off, for the target crosspoint button row (1st row to 4th row) to release. 93