Dell Brocade 6520 Command Reference Supporting Fabric OS v7.1.0 - Page 594
Partial, nsShow, nsCamShow, example, during FC-GS Name Server Queries.
View all Dell Brocade 6520 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 594 highlights
2 nsShow NOTES OPERANDS Partial Displays "Yes" if the device entry is incomplete; otherwise displays "No". Devices that are incomplete are displayed by the nsShow and nsCamShow commands, and have routing established, but are not considered during device discovery (for example, during FC-GS Name Server Queries). LSAN Displays "Yes" if the device is currently part of an active LSAN zone; otherwise displays "No". The following information is displayed only if the device has registered the information (for example, the switch automatically registers SCSI inquiry data for FCP target devices): • FC4s supported • IP address • Port and node symbolic names • Fabric Port Name. This is the WWN of the port on the switch to which the device is physically connected. • Port address or port IP address The execution of this command is subject to Virtual Fabric or Admin Domain restrictions that may be in place. Refer to Chapter 1, "Using Fabric OS Commands" and Appendix A, "Command Availability" for details. This command has the following optional operands: -r Replaces the time-to-live (TTL) attribute output with state change registration (SCR) information. This value indicates what type of RSCN a device registers to receive. Values include the following: SCR=0x00000000 Reserved. SCR=0x00000001 Fabric detected registration. Register to receive all RSCN requests issued by the fabric controller for events detected by the fabric. SCR=0x00000002 NX_Port detected registration. Register to receive all RSCN requests issued for events detected by the affected NX_Port. SCR=0x00000003 Register to receive all RSCN requests issued. The RSCN request returns all effected N_Port_ID pages. The following SCR values use the 4th byte of the SCR value and can coexist with the SCR values of 0x00000000, 0x00000001, 0x00000002, and 0x00000003. SCR=0x01000000 Principal switch RSCN registration. Register to receive proprietary RSCN (principal switch change). SCR=0x02000000 AG_QOS RSCN registration. -t Displays the device type. The device type is defined in terms of two attributes. The first attribute indicates the origination of the device as one of the following: Physical The device is connected to the NX_Port, using FLOGI to log in to the switch. 566 Fabric OS Command Reference 53-1002746-01