Netgear XCM8810 Chassis Hardware Installation Guide - Page 321
show inline-power slot
View all Netgear XCM8810 Chassis manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 321 highlights
NETGEAR 8800 Chassis Switch CLI Manual Example The following command displays summary inline power information for ports 1 to 3 on slot 3 on the switch: show inline-power info ports 3:1-3 Following is sample output from this command: Port State Class 3:1 delivering 3:2 delivering 3:3 searching class3 class3 ------ Volts 48.3 48.3 0.0 Curr (mA) 192 192 0 Power (Watts) 9.300 9.300 0.0 Fault None None None The following command displays detail inline power information for port 1 on slot 3: show inline-power info detail port 3:1 Following is sample output from this command: Port 3:1 Configured Admin State: enabled Inline Power State : delivering MIB Detect Status : delivering Label : Operator Limit : 16800 milliwatts PD Class : class3 Max Allowed Power : 15.400 W Measured Power : 9.400 W Line Voltage : 48.3 Volts Current : 193 mA Fault Status : None Detailed Status : show inline-power slot show inline-power slot Description Displays inline power information for the specified slot on the switch. Syntax Description slot Specifies the slot. Default N/A. Chapter 7. PoE Commands | 321