Netgear XCM8810 Chassis Hardware Installation Guide - Page 339
Filter Optimization, More Information, Example, BGP.Keepalive, mySTPFilter, STP.OutBPDU
View all Netgear XCM8810 Chassis manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 339 highlights
NETGEAR 8800 Chassis Switch CLI Manual If the only keyword is present following the severity value, then only the events in the specified component at that exact severity are included. Without the only keyword, events in the specified component at that severity or more urgent are included. For example, using the option severity warning implies critical, error, or warning events, whereas the option severity warning only implies warning events only. Severity all only is not a valid choice. Any EMS events with severity debug-summary, debug-verbose, or debug-data will not be logged unless debug mode is enabled. See the command enable log debug-mode on page 1350. Filter Optimization Each time a configure log filter command is issued for a given filter name, the events specified are compared against the current configuration of the filter to try to logically simplify the configuration. For example, if the command: configure log filter bgpFilter1 add events bgp.keepalive severity error only were to be followed by the command: configure log filter bgpFilter1 add events bgp severity info the filter item in the first command is automatically deleted since all events in the BGP.Keepalive subcomponent at severity error would be also included as part of the second command, making the first command redundant. More Information See the command show log on page 387 for more information about severity levels. To get a listing of the components present in the system, use the following command: show log components To get a listing of event condition definitions, use the following command: show log events To see the current configuration of a filter, use the following command: show log configuration filter {} Example The following command adds all STP component events at severity info to the filter mySTPFilter: configure log filter myStpFilter add events stp severity info The following command adds the STP.OutBPDU subcomponent, at the pre-defined severity level for that component, to the filter myStpFilter: configure log filter myStpFilter add events stp.outbpdu The following command excludes one particular event, STP.InBPDU.Drop, from the filter: Chapter 8. Commands for Status Monitoring and Statistics | 339