NETGEAR 8800 Chassis Switch CLI Manual strict Upon a fault detection, the switch takes the action configured by the configure sys-recovery-level slot command. Default The default setting is normal. Usage Guidelines On a NETGEAR 8800 series switch, use this command in conjunction with the configure sys-recovery-level slot [all | ] [none | reset | shutdown] command to implement your network's fault handling strategy. If you configure the strict parameter, the switch takes the action configured by the configure sys-recovery-level slot command, which can include logging only or restarting, rebooting, or shutting down the suspect device. System Behavior for the NETGEAR 8800 Series Switches Depending on your switch configuration, Table 9 shows how the 8800 series switches behave when the 8800 OS software detects a fault: Table 9. System behavior for the NETGEAR 8800 series switches Fault Handling Configuration Module Recovery Configuration configure sys-health-check configure all level normal sys-recovery-level slot none Same as above. configure sys-recovery-level slot reset Same as above. configure sys-recovery-level slot shutdown configure sys-health-check configure all level strict sys-recovery-level slot none Same as above. configure sys-recovery-level slot reset Same as above. configure sys-recovery-level slot shutdown Behavior The switch sends messages to the syslog. Same as above. Same as above. Same as above. 8800 OS reboots the affected switch or module. 8800 OS shuts down the affected switch or module. Chapter 8. Commands for Status Monitoring and Statistics | 359