Dell Force10 S55T FTOS Command Line Reference Guide for the S55 System FTOS 8. - Page 108
Command Example, Table 4-1., Descriptions for, output, show linecard brief, linecard
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 108 highlights
www.dell.com | support.dell.com Table 4-1 list the definitions of the fields shown in Figure 4-27. Table 4-1. Descriptions for show linecard output Field Line card Status Next Boot Required Type Current Type Hardware Rev Num Ports Up Time FTOS Version Jumbo Capable Boot Flash Ver Memory Size Temperature Power Status Voltage Serial Number Part Num Vendor ID Date Code Description Displays the line card slot number (only listed in show linecard all command output). Displays the line card's status. Displays whether the line card is to be brought online at the next system reload. Displays the line card type configured for the slot. The Required Type and Current Type must match. Use the linecard command to reconfigure the line card type if they do not match. Displays the line card type installed in the slot. The Required Type and Current Type must match. Use the linecard command to reconfigure the line card type if they do not match. Displays the chip set revision. Displays the number of ports in the line card. Displays the number of hours and minutes the card is online. Displays the operating software version. Displays Yes or No indicating if the line card can support Jumbo frames. Displays the two possible Bootflash versions. The [Booted] keyword next to the version states which version was used at system boot. List the memory of the line card processor. Displays the temperature of the line card. Minor alarm status if temperature is over 65° C. Lists the type of power modules used in the chassis: • AC = AC power supply • DC = DC Power Entry Module (PEM) Displays OK if the line voltage is within range. Displays the line card serial number. Displays the line card part number. Displays an internal code, which specifies the manufacturing vendor. Displays the line card's manufacturing date. Figure 4-29. Command Example: show linecard brief FTOS#show linecard 11 brief -- Line card 11 -- Status : online Next Boot : online Required Type : E48PF - 48-port GE line card with SFP optics (EF) Current Type : E48PF - 48-port GE line card with SFP optics (EF) Hardware Rev : Base - 1.0 PP0 - n/a PP1 - n/a Num Ports : 48 Up Time : 11 hr, 24 min FTOS Version : 6.1.1.0 Jumbo Capable : yes FTOS# 108 | Control and Monitoring