Dell Force10 S55T FTOS Command Line Reference Guide for the S55 System FTOS 8. - Page 379
reload-type, reload, Related, Commands, Syntax, show reload-type, Defaults, Command Modes, History
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 379 highlights
Use the reload-type command in BMP 2.0 to toggle between Normal and Jumpstart auto-configuration modes. The reload settings for the auto-configuration mode that you configure are stored in memory and retained for future reboots and BMP software upgrades. You can enter the reload command at any time to reload the switch in the last configured mode: Normal reload or Jumpstart mode. Related Commands show reload-type stop jump-start Display the current reload mode (Normal or jump-start mode) Stops the Jumpstart process to prevent a loop if the DHCP server is not found. show reload-type Display the currently configured reload mode. z Syntax show reload-type Defaults None Command Modes EXEC Privilege Command History Version 8.3.5.3 Version 8.3.3.8 Version 8.3.11.4 Version 8.3.10.1 Introduced on S55. Introduced on S60. Introduced on Z9000 Introduced on S4810. Usage Use the show reload-type command to check the currently configured auto-configuration Information mode (Jumpstart or Normal reload) on a switch running BMP 2.0. You can also use the show bootvar command to display the current reload mode for BMP 2.0 with the path of the FTOS image file retrieved from a DHCP server. Example FTOS#show reload-type Reload-Type : normal-reload [Next boot : normal-reload] Related Commands reload-type Configure the reload mode as normal or Jumpstart. Bare Metal Provisioning | 379