Dell Force10 S55T FTOS Command Line Reference Guide for the S55 System FTOS 8. - Page 503
minimum-links, port-channel failover-group
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 503 highlights
interface vlan shutdown Configure a VLAN. Disable/Enable the port channel. minimum-links c e s Configure the minimum number of links in a LAG (Port Channel) that must be in "oper up" status for the LAG to be also in "oper up" status. Syntax minimum-links number Parameters number Enter the number of links in a LAG that must be in "oper up" status. Range: 1 to 16 Default: 1 Defaults 1 Command Modes INTERFACE Command History Version 8.3.5.0 Version 8.1.1.0 Version 7.6.1.0 Version 7.5.1.0 pre-Version 6.2.1.0 Introduced on the S55. Introduced on E-Series ExaScale Introduced on S-Series Introduced on C-Series Introduced for E-Series Usage If you use this command to configure the minimum number of links in a LAG that must be in "oper up" Information status, then the LAG must have at least that number of "oper up" links before it can be declared as up. For example, if the required minimum is four, and only three are up, then the LAG will be considered down. port-channel failover-group c e s Access the PORT-CHANNEL FAILOVER-GROUP mode to configure a LAG failover group. Syntax port-channel failover-group To remove all LAG failover groups, use the no port-channel failover-group command. Defaults No default values or behavior Command Modes CONFIGURATION Command History Version 8.3.5.0 Version 8.1.1.0 Version 7.6.1.0 Introduced on the S55. Introduced on E-Series ExaScale Introduced for C-Series, E-Series, and S-Series Interfaces | 503