Dell Force10 S55T FTOS Command Line Reference Guide for the S55 System FTOS 8. - Page 893
show rmon history, show rmon hc-alarm, Command Example
View all Dell Force10 S55T manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 893 highlights
Example 2 Figure 34-7. show rmon hc-alarm index Command Example Force10#show rmon hc-alarm 1 RMON high-capacity alarm entry 1 object: 1.3.6.1.2.1.1.3 sample interval: 5 sample type: absolute value. value: 185638 alarm type: rising or falling alarm. alarm rising threshold value: positive. rising threshold: 1001, RMON event index: 1 alarm falling threshold value: positive. falling threshold: 999, RMON event index: 6 alarm sampling failed 0 times. alarm owner: 1 alarm storage type: non-volatile. alarm status: OK Force10# show rmon history c e s Display the contents of the RMON Ethernet History table. Syntax show rmon history [index] [brief] Parameters index brief (OPTIONAL) Enter the table index number to display just that entry. (OPTIONAL) Enter the keyword brief to display the RMON Ethernet History table in an easy-to-read format. Defaults No default behavior Command Modes EXEC Command History Version 8.3.5.0 Version 7.6.1.0 Version 6.1.1.0 Introduced on S55 Support added for S-Series Introduced for E-Series Example 1 Figure 34-8. show rmon history index Command Example Force10#show rmon history 6001 RMON history control entry 6001 interface: ifIndex.100974631 GigabitEthernet 2/0 bucket requested: 1 bucket granted: 1 sampling interval: 5 sec owner: 1 status: OK Force10# Remote Monitoring (RMON) | 893