Netgear XCM8806 Chassis Hardware Installation Guide - Page 193
con ip-mtu vlan, The following command clears slot 2 of a previously assigned module type
View all Netgear XCM8806 Chassis manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 193 highlights
NETGEAR 8800 Chassis Switch CLI Manual Syntax Description slot Specifies the slot number. Default N/A. Usage Guidelines All configuration information related to the slot and the ports on the module is erased. If a module is present when you issue this command, the module is reset to default settings. If a slot is configured for one type of module, and a different type of module is inserted, the inserted module is put into a mismatch state (where the inserted module does not match the configured slot), and is not brought online. To use the new module type in a slot, the slot configuration must be cleared or configured for the new module type. Use the enable mirroring to port tagged command to configure the slot. Example The following command clears slot 2 of a previously assigned module type: clear slot 2 The following command clears slot 4 of a previously assigned module type in a stack: clear slot 4 configure ip-mtu vlan configure ip-mtu vlan Description Sets the maximum transmission unit (MTU) for the VLAN. Syntax Description mtu vlan_name Specifies the IP maximum transmission unit (MTU) value. Range is from 1500 to 9194. Specifies a VLAN name. Default The default IP MTU size is 1500. Usage Guidelines The 8800 switches support IP fragmentation and path MTU discovery. Chapter 5. Commands for Configuring Slots and Ports on a Switch | 193