Netgear XCM8806 Chassis Hardware Installation Guide - Page 322
PoE Commands, NETGEAR 8800 Chassis Switch CLI Manual, Slot disabled
View all Netgear XCM8806 Chassis manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 322 highlights
NETGEAR 8800 Chassis Switch CLI Manual Usage Guidelines The output indicates the following inline power status for each system: • Configured power • Enabled • Disabled • System power surplus • Redundant power surplus • Power usage threshold • Disconnect precedence • Legacy-The status of the legacy mode, which allows detection of many non-standard PDs. The output indicates the following inline power status information for each slot: • Inline power status-The status of inline power. The status conditions are: • Enabled • Disabled • Firmware status-The operational status of the slot. The status conditions are: • Operational • Not operational • Disabled • Subsystem failure • Card not present • Slot disabled • Budgeted power-The amount of power, in watts, that is available to the slot. • Measured power-The amount of power, in watts, that currently being used by the slot. On a stack, if you do not specify a slot number, the command operates on all active nodes. This command operates only on nodes in the active topology. Example The following command displays inline power information for slot 3 on the switch: show inline-power slot 3 Following is sample output from this command: Inline Power System Information Configured : Enabled System Power Surplus : 1500 Watts available for budgeting Redundant Power Surplus : 465 Watts available for budgeting to maintain N+1 Power Usage Threshold : 70 percent (per slot) Disconnect Precedence : lowest-priority 322 | Chapter 7. PoE Commands