Netgear XCM8806 Chassis Hardware Installation Guide - Page 305
con inline-power priority ports
View all Netgear XCM8806 Chassis manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 305 highlights
NETGEAR 8800 Chassis Switch CLI Manual Syntax Description milliwatts port_list An integer specifying the maximum allowed power in milliwatts; the range is 3000 to 16800 mW. Note: If you attempt to enter a higher value, the switch returns an error message. Specifies one or more ports or slots and ports. Default 15400 mW. Usage Guidelines This command sets the power limit that a PD can draw on the specified ports. Range is 3000 to 16800 mW; the default value is 15400 mW. If the measured power for a specified port exceeds the port's operator limit, the power is withdrawn from that port and the port moves into a fault state. If you try to set an operator-limit outside the accepted range, the system returns the following error message: Error: Invalid operator-limit value. Must be in the range of 3000-16800 mW Example The following command sets the limit for legacy PDs on ports 3 - 6 of slot 5 to 10000 mW: configure inline-power operator-limit 10000 ports 5:3-5:6 configure inline-power priority ports configure inline-power priority [critical | high | low] ports Description Sets the PoE priority on the specified ports. Syntax Description critical | high | low port_list Sets the PoE priority for the specified ports. Specifies one or more ports or slots and ports. Default Low. Chapter 7. PoE Commands | 305