info-center timestamp, Syntax, Parameter, Description, Example, info-center trapbuffer, low 32 bits.
UPC - 662705493534
View all 3Com 5500G-EI manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 470 highlights
470 CHAPTER 12: USING SYSTEM MANAGEMENT COMMANDS info-center timestamp Syntax info-center timestamp { log | trap | debugging } { boot | date | none } undo info-center timestamp { log | trap | debugging } View System view Parameter log: Log information. trap: Trap information. debugging: Debugging information. boot: Time elapsing after system starts. Format: xxxxxx.yyyyyy, xxxxxx is the high 32 bits of the elapsed time (in milliseconds) after system starts, and yyyyyy is the low 32 bits. date: Current system date and time. It shows as yyyy/mm/dd-hh:mm:ss in Chinese environment and mm/dd/yyyy-hh:mm:ss in Western language environment. None: No timestamp format. Description Use the info-center timestamp command to configure the timestamp output format in debugging/trap information. Use the undo info-center timestamp command to disable the output of timestamp field. By default, datetime stamp is used. Example Configure the debugging information timestamp format as boot. system-view System View: return to User View with Ctrl+Z. [SW5500]info-center timestamp debugging boot [SW5500] info-center trapbuffer Syntax info-center trapbuffer [ size buffersize ] [ channel { channel-number | channel-name } ] undo info-center trapbuffer [ channel | size ] View System view Parameter size: Configure the size of the trap buffer.