Dell Brocade G620 Brocade 8.0.1 Fabric OS Command Reference - Page 1043
FAULTY, UNKNOWN, switch:user>, Blade Type, Status, CP BLADE, ENABLED
View all Dell Brocade G620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 1043 highlights
slotShow FAULTY UNKNOWN The blade is faulty because an error was detected. A fault code of 53 may also indicate the possibility of a rolling reboot detection (RRD) on the specified blade. In the case of an RRD, investigate and correct the cause, then reboot the control processor (CP) to recover the blade. The blade is inserted but its state cannot be determined. Notes The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to "Using Fabric OS Commands" and "Command Availability" for details. In a X6-4 chassis, slot 1 and 2 (Blade ID 175) are occupied by control processor blades and slot 5 and 6 (Blade ID 176) are occupied by core blades. In a X6-8 chassis, slot 1 and 2 (Blade ID 175) are occupied by the control processor blades and slot 7 and 8 (Blade ID 177) are occupied by core blades.. Operands This command supports the following operands: -p In addition to the basic slot status view, displays the following information about power consumption: • Total direct current (DC) power consumption for the chassis and individual values for each blade (in Watts). Usage for other components such the WWN card or fans is included in the calculation but not listed per component. Note that the data displayed in the "DC Power Consumption" column and in the summary field "Total DC Power consumption" indicate the maximum allowed power consumption, not a real-time value. Real-time power consumption data is displayed for 16G platforms only with the chassisShow command. • Total alternating current (AC) power consumption in Watts. This value indicates the maximum allowed AC power consumption; it is not a real-time value. • AC efficiency, as a percentage of total and BTU. • Power efficiency in Watts/port and Watts/Gb. -m In addition to the basic slot status view, displays the Brocade model name for each blade. Examples To display the status of all slots on a Brocade X6-8: switch:user> slotshow Slot Blade Type ID Status 1 CP BLADE 175 ENABLED 2 CP BLADE 175 ENABLED 3 AP BLADE 186 ENABLED 4 AP BLADE 186 ENABLED 5 SW BLADE 178 ENABLED 6 SW BLADE 178 ENABLED 7 CORE BLADE 177 ENABLED 8 CORE BLADE 177 ENABLED 9 AP BLADE 186 ENABLED 10 SW BLADE 178 ENABLED 11 SW BLADE 178 ENABLED 12 AP BLADE 186 ENABLED Brocade Fabric OS Command Reference 1019 53-1004112-02