Dell Brocade G620 Brocade 8.0.1 Fabric OS Command Reference - Page 598
Redirect, Partial, nsShow, nsCamShow, Device link speed, Port Properties, Name Server Queries.
![]() |
View all Dell Brocade G620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 598 highlights
nsShow Notes Redirect Displays "Yes" if the device is involved in frame redirection; otherwise displays "No". The device involved in frame redirection is specified as either "virtual" , "host", or "target". Partial Displays "Yes" if the device entry is incomplete; otherwise displays "No". Devices that are incomplete are displayed by the nsShow and nsCamShow commands, and have routing established, but are not considered during device discovery (for example, during FC-GS Name Server Queries). LSAN Displays "Yes" if the device is currently part of an active LSAN zone; otherwise displays "No". Device link speed Displays the link speed of the device, for example: 4G, 8G, 16G and 32G. Link speed of end devices that log in to the edge fabric through F_Port trunk display the bandwidth of the F_Port trunk. For example, if an 8 Gbps host attached to AG login to fabric through a 32 Gbps F_Port trunk, the device link speed for the 8 Gbps host is displayed as 32G. Port Properties Displays a list of port properties, for example: "SIM Port" for SIM ports If no properties are assigned, the field is not displayed. The following information is displayed only if the device has registered the information (for example, the switch automatically registers SCSI inquiry data for FCP target devices): • FC4s supported • IP address • Port and node symbolic names • Fabric Port Name. This is the WWN of the port on the switch to which the device is physically connected. • Port address or port IP address The execution of this command is subject to Virtual Fabric restrictions that may be in place. Refer to "Using Fabric OS Commands" and "Command Availability" for details. Operands This command has the following optional operands: -r Replaces the time-to-live (TTL) attribute output with state change registration (SCR) information. This value indicates what type of RSCN a device registers to receive. Values include the following: SCR=0x00000000 Reserved. SCR=0x00000001 Fabric detected registration. Register to receive all RSCN requests issued by the fabric controller for events detected by the fabric. SCR=0x00000002 NX_Port detected registration. Register to receive all RSCN requests issued for events detected by the affected NX_Port. 574 Brocade Fabric OS Command Reference 53-1004112-02
![](/manual_guide/products/dell-brocade-g620-brocade-801-fabric-os-command-reference-c7958e0/598.png)