Dell Brocade G620 Brocade 8.0.1 Fabric OS Command Reference - Page 21
Ge_crc, Ge_inv_len, Ge_los_of_sig, State_chg, Util, And Ip_util., Days_to_expire, Expired_certs
View all Dell Brocade G620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 21 highlights
What is new in this document • extnCfg - Added the --config -default and --config -clear operands. • fanDisable - Added note that the fan units on a Brocade X6 Director do not change their RPM speed to 0 and they take few minutes to change the speed to minimum RPM after being disabled. • faPwwn - Added a note that the ports must be disabled before executing the --enable and --assign options. • fcipLedTest - Added the behavior of this command on the Brocade SX6 extension blade. • fcipPathTest - Added details for Brocade SX6 extension blade. • fcrEdgeShow - This command displays information only for online EX_Ports. • fddCfg - Added a note that when a policy is set to strict mode, the manual distribution of the policy is not allowed. • firmwareDownload - Removed the following unsupported operands: -a, -t, -e, and -o. • flow - Added the predefined frame type 'Srr'. • fosExec - Added a note that the --domain operand can be executed only if the remote Fosexec feature is enabled on local and remote switches. • haShow - Added slot number details for the Brocade X6 Director. Added haShow command example on the Brocade X6 Director. • mapsConfig - Removed sw_critical and sw_marginal MAPS actions. These actions are always enabled by default. • mapsDb - Added new fields 'fenced circuits' and 'ports with highest zoned device ratio' fields. • mapsRule - Added the following monitoring systems under the respective category" • GE Port Health: GE_CRC, GE_INV_LEN, GE_LOS_OF_SIG, STATE_CHG, UTIL, and IP_UTIL. • FCIP health: IP_UTIL, IP_PKTLOSS, IP_RTT, and IP_JITTER. • Fabric performance impact: CRED_ZERO, THPUT_DEGRADE, and IT_FLOW. • Security health: DAYS_TO_EXPIRE, EXPIRED_CERTS, DID_CHG, FLOGI, and FAB_CFG. • Fabric state change: TEMP, ETH_MGMT_PORT_STATE, and FLASH_USAGE. • Switch status policy: FAN_AIRFLOW_MISMATCH. • msConfigure - Removed the following note: This command is supported only in AD0 and AD255 contexts. • msPlClearDB - Removed the following note: This command is supported only in AD0 and AD255 contexts. • msPlMgmtActivate - Removed the following note: This command is supported only in AD0 and AD255 contexts. • msPlMgmtDeactivate - Removed the following note: This command is supported only in AD0 and AD255 contexts. • msTdDisable - Removed the following note: This command is supported only in AD0 and AD255 contexts. • msTdEnable - Removed the following note: This command is supported only in AD0 and AD255 contexts. • nodeFind - The command is enhanced to accept WWN as single hexadecimal value. • nsShow - Added the 'Device link speed' field. • passwdCfg - Added the -charset, -allowuser, --hash, and --showhash options. • portCfg - Added details for Brocade SX6 blade and removed all references to Brocade 7800. Added the following options: sla, --proto-app, --rst-propagation, --non-terminated, and --load-leveling. Removed the --legacy option. • portCfgCompress - Added the following note: On 16 Gbps-capable platforms, both encryption and compression features are supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported. • portCfgDefault - Added the --help option. • portCfgEncrypt - Added the following note: On 16 Gbps-capable platforms, both encryption and compression features are supported. On 32 Gbps-capable platforms, only compression is supported and encryption is not supported. Brocade Fabric OS Command Reference xxi 53-1004112-02